Type Specification Code - Toshiba LF414 Instruction Manual

Electromagnetic flowmeter detector
Hide thumbs Also See for LF414:
Table of Contents

Advertisement

9.2 Type Specification Code

Table 9.2 Type Specification Code
Specification Code
1
2
3
4
5
6
7
8
L
F
4
1
D
E
F
G
H
J
K
L
A
B
C
D
E
F
G
H
J
K
L
9 10 11 12 13 14
Electromagnetic Flowmeter
Style
Wafer
Area of use
Division 2 Hazardous Location
Meter size
15mm ( 1/2" )
25mm ( 1" )
40mm ( 1 1/2" )
50mm ( 2" )
80mm ( 3" )
100mm ( 4" )
150mm ( 6" )
200mm ( 8" )
Mounting Structure
Hazardous location
cFMus, Division 2 approved
Connection flange standard
ANSI 150
ANSI 300
BS PN 10
BS PN 16
DIN PN 10
DIN PN 16
JIS 10K
JIS 16K
JIS 20K
Electrode Material
B
316L stainless steel
C
Ti (titanium)
D
Pt-Ir (platinum/iridium)
E
Ta (tantalum)
F
Hastelloy C
Lining Material
A
Alkali-resistant ceramic (alumina)
B
Acid-resistant ceramic (alumina)
C
Teflon PFA
Grounding Ring Material
C
316 stainless steel
D
316L stainless steel
E
Ti (titanium)
F
Ta (tantalum)
G
Pt-Ir (platinum/iridium)
H
Hastelloy C
Flow and calibration velocity range
A
0.3 to 10 m/s (standard range calibration)
B
0.3 to 10 m/s (specified range calibration)
C
0.1 to 10 m/s (specified range calibration)
Excitation and Signal Cables
A
not provided
B
30m cable, provided
C
other lengths, provided
Coating
A
no coating ( Standard for meter size 25mm to 100mm )
B
phthalic acid resin coating pearl-gray colored
C
black tar epoxy resin, thickness 0.3 mm
D
black tar epoxy resin, thickness 0.5 mm
- 48 -
Description
type
Detector/Converter combined type
Detector/Converter separate type
( Standard for meter size 15mm, 150mm and 200mm )
○:Standard
6F8A0870
15mm
to
100mm
(standard)
△:Option
-:Not available
150mm
and
200mm

Advertisement

Table of Contents
loading

Table of Contents