Toshiba LF414 Instruction Manual page 25

Electromagnetic flowmeter detector
Hide thumbs Also See for LF414:
Table of Contents

Advertisement

Through Bolts
Meter size
P.C.S
15mm 1/2"
4
25mm
1"
4
40mm 1 1/2"
4
50mm
2"
4
80mm
3"
4
100mm 4"
8
150mm 6"
8
200mm 8"
8
DIN/BS 10, DIN/BS 16
Through Bolts
Meter size
P.C.S
15mm
4
25mm
4
40mm
4
50mm
4
80mm
8
100mm
8
150mm
8
200mm
8
200mm
12
(DIN/BS 16)
Table 4.1 Bolt length and Nut tightening torque
ANSI class 150
Tightening
torque
Dia-
Length
[N・m]
meter
[mm]
1/2"
150
12 to 15
1/2"
170
21 to 26
1/2"
195
32 to 40
5/8"
215
52 to 65
5/8"
225
71 to 88
5/8"
235
52 to 65
3/4"
355
104 to 130
3/4"
430
146 to 183
Tightening
torque
Dia-
Length
[N・m]
meter
[mm]
M12
150
16 to 19
M12
165
27 to 34
M16
190
58 to 72
M16
205
78 to 98
M16
210
54 to 67
M16
220
79 to 99
M20
340
164 to 205
(DIN/BS 10)
M20
410
146 to 183
M20
410
156 to 195
- 24 -
ANSI class 300
Through Bolts
Dia-
Length
P.C.S
meter
[mm]
4
1/2"
155
4
5/8"
180
4
3/4"
215
8
5/8"
220
8
3/4"
240
8
3/4"
255
12
3/4"
375
12
7/8"
460
JIS 10K
Through Bolts
Dia-
Length
P.C.S
meter
[mm]
4
M12
150
4
M16
170
4
M16
190
4
M16
200
8
M16
210
8
M16
215
8
M20
340
12
M20
410
6F8A0870
Tightening
torque
[N・m]
25 to 31
53 to 66
96 to 120
52 to 65
85 to 106
125 to 156
138 to 173
227 to 284
Tightening
torque
[N・m]
10 to 13
22 to 28
32 to 40
43 to 53
27 to 34
37 to 46
70 to 88
60 to 75