Download Print this page

Cable Connection - Toshiba LF414 Instruction Manual

Electromagnetic flowmeter detector
Hide thumbs

Advertisement

Table of Contents
6F8A0870

5.4.2 Cable Connection

Connect and install the terminal-treated cables to the terminal block.
*Connect the cables to the terminal block securely. A loose connection may cause incorrect
measurement. After connecting a cable, try to pull it to check whether it has been connected securely.
Referring to combined converter's manuals of "Connections and Grounding", connect each cable to the
terminal block. Tighten the screws of the terminal block tightly to ensure a secure connection. A loose
connection may cause incorrect measurement. After connecting a cable, try to pull it to see whether it has
been connected securely.
Phillips screwdriver
* The appropriate torque for tightening
the terminal board screw is 1.2 N.m.
Terminal block
Figure 5.5 Connecting a Cable to Terminal Block
- 36 -

Advertisement

Table of Contents
loading

  Also See for Toshiba LF414

  Related Manuals for Toshiba LF414