Troubleshooting

Symptom
Door stops or moves very slowly
under battery power
Door will not operate when
mains power is disconnected.

Maintenance

To ensure a long trouble free life for your battery backup it is recommended you run the testing procedure on a monthly basis.
Batteries should not need replacing for 4 - 5 years.
Testing Procedure:
a. Press the transmitter to activate the opener.
b. Whilst the door / gate is in motion disconnect power. The door / gate should complete the cycle as normal.
c. Wait for the door / gate to finish is travel.
d. Press the transmitter to activate the opener.
e. Whilst the door / gate is in motion reconnect power. If the door / gate stopped or moved very slosly under battery power,
ensure mains power is connected for 24 - 48 hours to recharge the batteries. Test the opener again under battery power to
ensure batteries are working effectively.

Warranty

WARRANTY
ACCESSORIES
6 - 8 Fiveways Boulevard, Keysborough, VIC, Australia 3173
P: 1300 133 944
E: sales@automatictechnology.com.au
W: www.automatictechnology.com.au
© Nov 2018 Automatic Technology (Australia) Pty Ltd. All rights reserved. No part of this document may be reproduced without prior permission. In an ongoing
commitment to product quality we reserve the right to change specification without notice. E&OE.
Possible cause
Batteries may be weak or have
no charge
Batteries / charger board may
not be connected properly.
Batteries may have no charge
Faulty Charger board
Faulty Batteries
This warranty is to be read in conjunction with the owner's copy of
the opener installation instruction.
1 year
Remedy
Connect mains power and allow the batteries
to charge. This may take 24 - 48 hours to reach
maximum charge capacity.
Check wiring.
Connect mains power and allow the batteries
to charge. This may take 24 - 48 hours to reach
maximum charge capacity.
Disconnect the charger board from batteries and
control board. Check voltage of the charger board.
Voltage should be approximately 27.5V.
Disconnect the batteries from the charger board.
Check the voltage of the each battery. Voltage
should not drop below 10V.
B&D Doors is a division of B&D Australia Pty Ltd
ABN 25 010 473 971
B&D Doors, 34-36 Marigold St, Revesby, NSW, 2212
P: 13 62 63
E: enquires@bnd.com.au
W: www.bnd.com.au

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Automatic Technology Battery Backup Gen 2 Kit and is the answer not in the manual?

Table of Contents