To reduce condensation,
insulate any ducting which p asses through unheated
areas. Slope the
duct gently d ownwards
tothe hood, todrain c ondensation
and reduce lintbuild up, A void s ag
orloops i ntheduct as they may collect and store w ater and accumulate
lint.
Before using a nexisting exhaust duct s ystem f oradryer ensure that:
No pEastic
orother potentially
combustibEe
duct o rflexible metal foilducting h as b een u sed.
The duct i snot p ierced, kinked o rcrushed.
The duct d oes n ot
e xceed the maximum
recommended
length for the new dryer.
The exhaust hood damper opens and closes freely and with sufficient
movement.
Static pressure in the exhaust ducting
does not exceed 1 inch (250Pa), or s not less than 0
inches of water column
fie. negative
pressure), when measured with a manometer
in the first 6
inches of the duct, wth the dryer running
on Air Dry (no heat) setting.
The exhaust duct system meets aJ[ relevant local, state and national
codes.
All ducting
should be inspected
and cleaned at least once a year to remove accumulated
lint.
Frequently
check that the damper on the exhaust hood moves sufficiently
and opens and
Mobile
Home Installations
A Mobile
Home Installation
Kit is available (see Accessor es page 7).
Determine
vent duct length
This dryer can only be vented from the rear and must be exhausted to the outdoors,
.... _
Fig.70 Reclrvenling only
Different
types of vent arrangements
are shown below.
i
fig. 11V_'ndngoptions