Do you have a question about the ED56 Series and is the answer not in the manual?
Questions and answers
Suzette
February 18, 2025
how to put a back panel back on ED56 F&P dryer To put right screws in right holes
1 comments:
Mr. Anderson
February 18, 2025
To reattach the back panel on a Fisher & Paykel ED56 dryer, follow these steps:
1. Position the back panel in place. 2. Insert and secure 21 screws around the edge of the panel. 3. Insert and secure 2 screws in the middle of the panel. 4. Ensure the bearing support ring is properly aligned with the air duct. 5. Secure the bearing support ring by inserting and tightening 7 screws. 6. Confirm that the 6 drum bearings are correctly positioned in the bearing ring. 7. Reassemble in reverse order of disassembly.
Ensure all screws are tightened securely to prevent misalignment.
Contents Introduction Safety and warnings Installation instructions Installation options Installation – Electronic and Manual 4.5 kg dryers Installation – Manual 3.5 kg dryers Specifications Dryer wall mounting instructions Before you dry Sorting and loading Cleaning the lint filter Electronic dryer Using your dryer Dryness levels 1 hour settings...
Introduction Congratulations on purchasing a Fisher & Paykel dryer. Your new dryer will give you the convenience of tumble drying and your clothes the advantage of not being subjected to the harsh overdrying effects of the sun. Your clothes will feel softer, retain their shape better and will require less ironing.
Safety and warnings WARNING! Fire Hazard Only dry fabrics that have been washed with water. Do not use heat to dry articles containing foam rubber or similarly textured rubber-like materials. Dry on Airing. A clothes dryer produces combustible lint and must be exhausted outdoors. Take care to prevent the accumulation of lint around the exhaust opening and surrounding area.
Page 6
Safety and warnings Spontaneous combustion Important! To reduce the risk of fire in a tumble dryer the following should be observed: Items that have been spotted or soaked with vegetable oil or cooking oil are a fire hazard and should not be placed in a tumble dryer. Oil-affected items can ignite spontaneously, especially when exposed to heat sources such as a tumble dryer.
AD39 Inverted Panel Part No. 427560P Washer AD55 Inverted Panel Part No. 427560 5 series = 415 mm ED56 Inverted Panel Part No. 427562 Minimum 6 series = 455 mm Wall Mounting Kit Part No. 502067 lid clearance...
Installation – Electronic and Manual 4.5 kg dryers Correct installation is very important for all dryers to ensure maximum efficiency and safety. Important! Never run the dryer unless the airflow system is free from obstruction. There must be adequate ventilation to avoid the backflow of gases into the room from appliances burning fuels, including open fires, when operating the dryer.
Page 9
Installation – Electronic and Manual 4.5 kg dryers Flush venting The dryer is vented through a hole in the wall, using a galvanised metal pipe or flexible hose. This is suitable for floor and wall mounted dryers installed against an outside wall. Flexible Hose 400 mm Part No.
Installation – Manual 3.5 kg dryer Dryer position The Manual 3.5 kg dryer is front venting. The air is taken in through the grill at the rear of the dryer and vented out through the grill in the door. The dryer should be positioned so that the air intake at the rear is unrestricted.
Dryer wall mounting instructions Tools and parts required: 1 drill and 3 mm bit 1 Phillips screw driver 2 wood screws 14 x 50 timbertite screws 1 screw driver 1 helper to lift dryer onto bracket Extra tools and parts for mounting onto a concrete wall: 1 6 mm bit 2 M6 x 50 expanding bolts 1 adjustable spanner...
Page 12
Dryer wall mounting instructions 95 mm Dryer Bracket Ensure bracket is securely fastened at both ends 114.5 mm (eg into the stud). Fit timber slats if necessary 127 mm Ceiling 70 mm Bracket holes Fit spacers as shown For the average person the recommended height for the...
Sorting and loading To get the most efficient use of your dryer we recommend you sort your loads. Before drying Look for a care label on your clothes. This will tell you if they can be safely tumble dried. Close zippers, hooks and eyes, etc to reduce snagging and tangling. Drying times Drying very small loads is inefficient.
Cleaning the lint fi lter Electronic and Manual 4.5 kg dryers It is important to clean the lint filter regularly, as the lint produced in the drying process can become a fire hazard if it is allowed to accumulate in or around your dryer. The lint filter is located in the door opening.
Electronic dryer Your Electronic dryer takes the guess work out of choosing drying times by sensing the dryness of the load. When your dryer senses that the clothes have dried to the dryness level you have selected, the dryer will automatically turn itself off. Using your dryer Clean the lint filter before every load.
Electronic dryer 1 hour setting The 1 hour setting is a manual cycle which dries continuously for 60 minutes. The manual cycle does not sense when your clothes are dry. You can use the 1 hour setting when using a drying rack to dry shoes, hats and other items that are best dried without tumbling.
Electronic dryer Temperature settings This dryer has 3 temperature settings; regular, low and airing. The REGULAR setting is for drying most fabrics. The LOW setting is for drying delicates and synthetics. It is half heat so the temperatures are lower for maximum care of the fabrics. The AIRING setting is a cycle designed to freshen up garments.
Manual dryers The Manual dryers have been designed so you can select how long you want the clothes to dry for. So you know exactly when your clothes will be ready. Using your dryer Clean the lint filter before every load. Load the clothes into the dryer.
Manual dryers Drying times With your new dryer it may take a few trials before you can accurately predict the correct drying time for each individual load. As a guide we have included some examples of loads and drying times. These times are approximate only, based on the garments being spun at the maximum spin speed suitable for the wash load.
Drying rack 4.5 kg dryers only A drying rack is available to dry shoes, hats and other items that are best dried without tumbling. How to use the drying rack Place the locating pin at the end of the drying rack into the hole in the centre of the rear of the dryer drum.
Operating problems If your dryer is not operating properly use the checklist below to find the possible solution. Pressing POWER or setting the timer does not turn the machine on. Is the electrical cord plugged in? Is the power switched on at the wall? Is the door securely closed? Could your household power supply be at fault.
Manufacturers warranty The purchaser automatically receives a 2 year Manufacturer’s Warranty with the purchase of this Product covering parts and labour for servicing within the country of purchase. Fisher & Paykel undertakes to: Repair or, at its option, replace without cost to the owner either for material or labour any part of the Product, the serial number of which appears on the Product, which is found to be defective within TWO YEARS of the date of purchase.
Customer care Check the things you can do yourself. Refer to your User Guide and check: Your appliance is correctly installed You are familiar with its normal operation You have read the Trouble Shooting section If after checking these points you still need assistance please refer to the following: In New Zealand if you need assistance...* Call your Fisher &...
Need help?
Do you have a question about the ED56 Series and is the answer not in the manual?
Questions and answers
how to put a back panel back on ED56 F&P dryer To put right screws in right holes
To reattach the back panel on a Fisher & Paykel ED56 dryer, follow these steps:
1. Position the back panel in place.
2. Insert and secure 21 screws around the edge of the panel.
3. Insert and secure 2 screws in the middle of the panel.
4. Ensure the bearing support ring is properly aligned with the air duct.
5. Secure the bearing support ring by inserting and tightening 7 screws.
6. Confirm that the 6 drum bearings are correctly positioned in the bearing ring.
7. Reassemble in reverse order of disassembly.
Ensure all screws are tightened securely to prevent misalignment.