IlllnstaIIIIlation instructions
Location
requirements
The area in which the dryer is located must be
kept clear and free from combustible
materials,
gasoJine and other flammabJe vapors and
liquids. A dryer produces combustibJe
[int so the
area around the dryer must be cleaned reguJarJy
to keep it free of lint.
Fig.3Rear w*nting
This dryer can only be vented from the rear and must be exhausted
to the outdoors.
Alcove or closet installation
When installing
a dryer
in a cbsedalcove
it must be exhausted
_o the outdoors.
No other
fuel burning
appliance
can be installed
in the same closet or a[coveo
The top opening
area in the door must be a minimum
of 48 square inches (31 O0 mm 2) and the
bottom
opening
area must have a minimum
of 24 square inches (1550 mm 2) These openings
must never be obstructed
(a [ouvred door with the minimum
air opening
is acceptable).
Minimum
installation
cJearances are required
but more cJearance is recommended.
L
ii
ii
1" (25 mm)
1"(25 mm)
I" (25 mm)
rain 565/6"
(1430 mm)
fig.4 Minimum deomnces
.._1b.......
.I i_m
[ J
II
rain 2" (50 ram) rain 3" (76 ram)

Advertisement