Fisher & Paykel AeroSmart Series Installation Instructions And User Manual page 14

Clothes dryer
Table of Contents

Advertisement

Available languages

Available languages

¸il ¸liiii ¸il ¸liiiii
¸I ¸II ¸iiiil
¸ii i i iiiil
¸il ¸ii'i iiiiiii
¸il ¸iiiii:ii
¸iliiii'liiii
¸I ¸ii'iii iiii
¸I ¸ii iiiiiiil
lnstalllllation ilnstlructions
The dryer must be ve_ed
to the outdoo_s_
Ose rigid or thick wall fle×iMe
metal exhaust
duct,
Oo _ot use a p_astic exhaust
duct,
Do not use a meta_ foi_ exhaust
duct.
Failure to follow
these instructions
can result in death or fire.
The dryer must be exhausted
to the outdoors.
This will prevent the build up of lint and moisture
in the room in which it is located and reduce the risk of fire.
This appliance
must always be vented to the outdoors.
Exhaust ducting
products can be purchased from your local Appliance
store or Hardware store.
Plastic or metal foil flexible duct can kink, sag, be punctured,
reduce airflow, extend drying
times and affect dryer operation.
A minimum
of 4 inch (100 ram) thick wall flexible metal or rigid galvanised
metal duct must be
used. Using ducts larger than 4 inches (100 mm) diameter
may result in more lint accumulating.
Using straight
rigid metal ducting
will minimize
lint accumulation.
Thick wall flexible metal
ducting
may be used but care must be exercised to avoid sharp bends which may squash the
duct and cause blockages.
Do not use plastic ducting
or thin wall flexible metal ducting
Use duct tape to secure joints. Do not use screws as they collect lint.
Keep ducting
as short and straight
as possible. Do not exceed the maximum
exhaust duct
lengths stated later in these nstalJation
nstructions.
Do not exhaust the dryer into any other duct, chimney
or gas vent, a wall, a ceiling or any
concealed space in a building
Do not exhaust the dryer under a house or mobile
home or a
porch, or into a window
well or other area that will accumulate
lint.
The exhaust duct should end with an exhaust hood with a
swing out damper to prevent
back drafts and entry of wild
life. Never use exhaust hoods with a magnetic
damper
The
hood should have at least 12 inches (305 mm) clearance
between
the bottom
of the hood and the ground or other
obstruction
The hood opening
should point down. Never
install a screen over the exhaust outlet.
_ig.9 Yxh_ust hood minimum
ground deoro,nce
,,,,,,,,,,,,,,,,,,,,,,
i)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aerosmart dg62t27cAerosmart de62t27c

Table of Contents