Figure 57
5. Make a note of the cable data on the cover of the OVP Module.
6. Reinsert the six screws in the DF and tighten them with a T30 Torx
3.7.4

Connecting Transmission Cables, Fiber Optic - Alternative 4

Note: Handle the fiber optic cables with care and do not exceed the minimum
1. Ensure that the DF is not fastened in place, and that the space beneath
2. Remove the rubber sealing in the DF cable entry closest to the OVP
3. Remove the end nut from the fixed cable gland on the fiber optic cable and
4. Remove the rubber sealing from the cable entry to be used.
5. Insert the cable gland in of the DF cable entry as shown in the figure above.
6. Reattach the nut and tighten it, using a 26 mm open-ended wrench.
1/1531-COH 109 2073 Uen H 2006-11-06
Cable Connections
screwdriver.
bending radius of 35 mm.
it is accessible.
module to be used.
pass the cable through one the of cable inlets as shown in the figure above.