To connect a coaxial cable to an Overvoltage Protection (OVP) module, do
the following:
Note: The instructions describe the connections to one connection block of
1. Ensure that the DF is not fastened in place, and that the space beneath it is
2. Remove the rubber sealing in the DF cable entry closest to the OVP
3. Insert the cable gland and tighten it with a 20 mm open-ended wrench.
4. Pass at least 170 mm of the cable through the cable. See 2 in the figure
Figure 48
5. Strip 170 mm of the outer layer of insulation from the cable, using a wire
1/1531-COH 109 2073 Uen H 2006-11-06
Single coaxial cables
Two coaxial cables are connected to one connection block of an OVP
module.
an OVP module.
accessible. See Section 3.3 on page 10.
module to be used.
Note: If single coaxial cables are used, then two cable inlets are needed
for connection to one connection block of an OVP module.
See 1 in the figure below.
below.
Cable Gland Attachment and Cable Routing
stripper. See figure below.
Procedure
41