Ericsson RBS 3107 Installation Instructions Manual page 17

Hide thumbs Also See for RBS 3107:
Table of Contents

Advertisement

Improper handling of batteries can result in the batteries short-circuiting, which
can result in serious injury due to high energy levels. Exercise the necessary
care when working with batteries.
1.
2.
3.
4.
Table 2
Cable Cross-Sectional Area
95 – 185 mm²
16 – 70 mm²
5.
6.
1/1531-COH 109 2073 Uen H 2006-11-06
Ensure that the positive (+) cable is disconnected from the external batteries
before following the instruction below.
Remove the bottom cover plate of the DC filter and the cable glands.
Insert and connect the stripped
cables from the external batteries to
the DC filter.
Note: The figure shows the bottom
of the DC filter.
Position the correct side of the cable clamps for the cross-sectional area of
the cable in accordance with the table below.
Cable Clamp Mounting Alternatives
Tighten the nuts to 7 – 9 Nm torque.
Tighten the cable glands.
Caution!
Cable Clamp Inscription, Facing
Upwards
CU 95 – 185
CU 16 – 70
Procedure