GENERATOR COIL RESISTANCE
• Disconnect the generator coupler 1 .
Measure the resistance between the B/R lead wire and ground
using the multi-circuit tester. If the resistance is not within the
specified value, replace the generator coil with a new one.
09900-25008: Multi-circuit tester set
Tester knob indication: Resistance (Ω)
Generator coil resistance:
GENERATOR NO-LOAD PERFORMANCE
• Disconnect the regulator/rectifier coupler 1 .
• Start the engine and keep it running at 5 000 r/min.
Measure the voltage between the B/R wire of regulator/rectifier
coupler and ground using the multi-circuit tester.
If the tester reads under the specified value, replace the genera-
tor with a new one.
09900-25008: Multi-circuit tester set
Tester knob indication: Voltage (~)
Generator no-load performance
30 V (AC) and more at 5 000 r/min (When engine is cold)
0.6 – 2.0 Ω (Black/Red – Ground)
ELECTRICAL SYSTEM
6-7
B/R
B/R
V