23
Start-up of the lock
The lock installation as well as cabling and the first battery installation are described in the installation manual.
As long as the lock system has not been put into operation, it can be opened using the assembler code.
The assembler code is intended for lock mounting at the factory and not for further permanent use.
For correct start-up of the lock the master code must be activated correctly according to chapter 8.2, this makes the assembler
code invalid.
If the start-up or partial start-up has already been performed by the safe manufacturer or distributor, the corresponding
information is specified in its manuals/notes. Furthermore, the safe manufacturer or distributor can document the set
master code in this manual. For this information refer to the field highlighted in gray in chapter 1 page 4, "Master code
set by the distributor resp. safe manufacturer".
23.1
Opening with assembler code
Description
1. Press
and
Turn the actuating knob within 4 seconds through 90°
2.
Table 33: Opening with assembler code
As long as the assembler code is used for opening (master is not activated yet), there is no guard time for incorrect code
inputs according to chapter 10.5 and no take-off contact signal message according to either.
23.2
Activating master
Now activate the master with the storage unit open (to have every time access to the storage unit and the lock).
Description
1. Press
and
2. Enter the new master code
(00 = ID, X = freely selected 6-digit combination [0..9])
3. Confirm the new master code with
Table 34: Activating master
Then check the performed programming with the storage unit still open. To do so, proceed according to chapter 10.1.
If the Incorrect code signal is output, the procedure must be repeated since both codes do not match or the ID (here
00) has been entered incorrectly.
Changing of the master code can be canceled any time by pressing
canceled if no input is performed within 30 seconds.
24
Programming functions for the master
All programming functions described here require the master code for authorisation.
For security reasons, programming and testing of programming should always be performed with the secure storage unit
open (to have every time access to the storage unit and the lock). Programming can be performed any time individually
and without waiting times (exception - guard times), even if the double code and/or OD/OST are activated. All
programming processes can be canceled by pressing
performed within 30 seconds.
Version 2014-02-28
Page 34 of 48
Then open the storage unit.
Operating instructions 82132/3xxx CB 30
and
and
twice. Alternatively, the input can be canceled if no input is
2x
2x
twice. Alternatively, the process can be
2x
3x
3x
2x
3x
3x
2x
3x
3x
2x
3x
3x