Command Manual (For Soliton) – Stack-Cluster
H3C S3100 Series Ethernet Switches
Description
Use the snmp-host command to configure a shared SNMP NMS for the cluster on the
management device.
Use the undo snmp-host command to remove the shared SNMP NMS setting.
By default, no shared SNMP NMS is configured.
After setting the IP address of an SNMP NMS for the cluster, the member devices in the
cluster can send trap messages to the SNMP NMS through the management device.
Note that, you can only use the commands on a management device.
For how to configure a switch to send trap messages to the SNMP NMS, refer to
Information Center Operation.
Examples
# Configure SNMP NMS address 1.0.0.9 on the management device for the cluster.
<aaa_0.Sysname> system-view
System View: return to User View with Ctrl+Z.
[aaa_0.Sysname] cluster
[aaa_0.Sysname-cluster] snmp-host 1.0.0.9
2.3.22 tftp get
Syntax
tftp { cluster | tftp-server } get source-file [ destination-file ]
View
User view
Parameters
cluster: Downloads files through the shared TFTP server of the cluster.
tftp-server: IP address or host name of the TFTP server.
source-file: Name of the file to be downloaded from the shared TFTP server of the
cluster.
destination-file: Name of the file to which the downloaded file will be saved on the
switch.
Description
Use the tftp get command to download a file from a specific directory on the shared
TFTP server to the switch.
You can use the tftp-server command on the management device to configure the
shared TFTP server of the cluster, which is used for software version update and
Chapter 2 HGMP V2 Configuration
2-40
Commands