14. Electrical connection
The installation must be carried out by an approved electrical
contractor. Observe VDE regulations and all local regulations of your
power supply utility company.
The applicable national regulations and conditions, as well as those
of the local utility company must be observed for electrical installation
work.
An omnipolar isolator with at least 3 mm contact separation must be
integrated in the power cable upstream of the appliance.
A connection box must also be installed on site.
Do not route sensor leads alongside 230 V cables.
Danger through "live" electrical components.
Please note: Turn OFF the omnipolar isolator before removing the
casing.
Never touch electrical components or contacts when the isolator is in
the ON position. This carries a risk of electrocution that could result
in injury or death.
During servicing and installation work, isolate the entire system from
the power supply at all poles, to prevent risk of electrocution.
No mains isolator on the appliance. When working on the boiler,
Please note
always ensure that there is no voltage by opening the omnipolar
isolator or removing the external mains fuse.
First undo the central screw at the bottom of the front casing.
Push in the two locking hooks at the bottom left and right and pull the casing forwards.
Lift the front casing upwards to release and remove it.