Design Information, Underfloor Heating / Dhw Circulation - Wolf FGB-K Series Installation And Maintenance Instructions For Contractors

Wall mounted gas condensing/combi boiler
Hide thumbs Also See for FGB-K Series:
Table of Contents

Advertisement

Underfloor heating system
If pipes which are impermeable to oxygen are used, an
underfloor heating system can be connected directly to a
heat source with up to 10 kW heating output, depending on
the system pressure drop.
Always install a temperature limiter for the underfloor heating
system to protect the pipes from overheating.
The output of the integrated pump should be increased if
underfloor heating is connected (parameters HG16 and
HG17). Recommendation HG16 Þ 75% and HG17 Þ 100%
For connection of an underfloor heating system with an
output requirement in excess of approx. 10 kW, a 3-way mixer
(accessories MM) and an additional pump are required.
Install a regulating valve in the return; this can be used to
reduce the excessive head of the additional pump if required.
Ensure the system user cannot adjust any
Please note
regulating valves.
When using pipes that are diffusion-proof to
oxygen, it is necessary to provide system
separation by means of a heat exchanger.
Inhibitors may not be used.
If an additional heating circuit is operated in parallel to the
underfloor heating system, it must be hydraulically matched
to the underfloor heating system.
NTC
Sensor resistances
3064458_201811
32. Design information, underfloor
heating / DHW circulation
Flow temperature sensor, cylinder temperature sensor, DHW outlet temperature
sensor, outside temperature sensor, return temperature sensor, flue gas temperature
sensor
Temp. °C
Resist. Ω
Temp. °C
-17
40810
-16
38560
-15
36447
-14
34463
-13
32599
-12
30846
-11
29198
-10
27648
-9
26189
-8
24816
-7
23523
-6
22305
-5
21157
-4
20075
-3
19054
-2
18091
-1
17183
0
16325
1
15515
2
14750
3
14027
4
13344
5
12697
6
12086
7
11508
8
10961
9
10442
10
9952
11
9487
12
9046
13
8629
14
8233
15
7857
16
7501
Fig: Underfloor heating system (example
For heating systems with plastic pipes, we recommend the
use of impermeable pipes to prevent the diffusion of oxygen
through the pipe walls.
When
Please note
conjunction with an underfloor heating system,
we recommend sizing the usable volume of a
diaphragm expansion vessel 20 % larger than
recommended by DIN 4807-2. An diaphragm
expansion vessel of insufficient size results in
oxygen ingress into the heating system, causing
corrosion damage.
Resist. Ω
Temp. °C
17
7162
51
18
6841
52
19
6536
53
20
6247
54
21
5972
55
22
5710
56
23
5461
57
24
5225
58
25
5000
59
26
4786
60
27
4582
61
28
4388
62
29
4204
63
30
4028
64
31
3860
65
32
3701
66
33
3549
67
34
3403
68
35
3265
69
36
3133
70
37
3007
71
38
2887
72
39
2772
73
40
2662
74
41
2558
75
42
2458
76
43
2362
77
44
2271
78
45
2183
79
46
2100
80
47
2020
81
48
1944
82
49
1870
83
50
1800
84
operating
the
condensing
Resist. Ω
Temp. °C
1733
85
1669
86
1608
87
1549
88
1493
89
1438
90
1387
91
1337
92
1289
93
1244
94
1200
95
1158
96
1117
97
1078
98
1041
99
1005
100
971
101
938
102
906
103
876
104
846
105
818
106
791
107
765
108
740
109
716
110
693
111
670
112
649
113
628
114
608
115
589
116
570
117
552
118
boiler
in
Resist. Ω
535
519
503
487
472
458
444
431
418
406
393
382
371
360
349
339
330
320
311
302
294
285
277
270
262
255
248
241
235
228
222
216
211
205
93

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fgb seriesFgb-28Fgb-k-35Fgb-35Fgb-k-28

Table of Contents