Electrical Connection - Wolf CGB-75 Installation And Operating Instructions Manual

Wall mounted gas condensing boiler
Table of Contents

Advertisement

General information
The installation may be carried out only by
an approved electrical contractor. Observe
VDE regulations [Germany] and all local
regulations of your power supply utility.
For installation in Austria: The ÖVE reg-
ulations and requirements and those of
your local power supply utility must be
observed.
An omnipolar isolator with at least 3 mm
contact separation must be integrated in
the power cable upstream of the appliance.
A connection box must also be installed
on site.
Never route sensor leads alongside 230 V
cables.
22
12. Electrical connection
Danger through 'live' electrical compo-
nents.
Please note: Turn off the ON/OFF switch
before removing the casing.
Never touch electrical components or con-
tacts when the ON/OFF switch is in the ON
position. There is a danger of electrocution,
resulting in a risk to health or death.
The main terminals are 'live', even when
the ON/OFF switch is in the OFF position.
During servicing and installation work,
isolate the entire system from the power
supply across all poles, otherwise there
will be a risk of electrocution.
3062555_201804