Specifications - Tiger FLX10 Operator's Manual

Tiger lawn mower accessory user manual
Table of Contents

Advertisement

MAINTENANCE
Lubrication Chart

Specifications

FLX15 Hydraulic Circuit Requirements
Hoses and breakaways are provided in order to connect to a 15' rotary cutter with individual single acting wing
circuits. A total of 4 hydraulic circuits are required. Two of the circuits require float positions on the control
valves in order to operate the single acting wing circuits on the rotary cutter.
FLX10 Hydraulic Circuit Requirements
Hoses and breakaways are provided in order to connect to a 10' rotary cutter with single acting wing circuit. A
total of 3 hydraulic circuits are required. One of the circuits requires a float position on the control valve in
order to operate the single acting wing circuit of the rotary cutter.
Solenoid Valve Kit
An optional solenoid valve kit is available for the FLX15 and FLX10 to reduce the number of tractor circuits
require to operate the FLX15, from 4 to 3 circuits, and the FLX10, from 3 to 2 circuits.
The kit includes additional hoses and breakaways in order to operate the wing lift cylinders in double acting
mode and does not require a float position on the tractor control valves.
Maintenance Section 5-7
FLX15/10 04/06
© 2006 Alamo Group Inc.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flx15

Table of Contents