Verifying TFTP Download Status
After you have downloaded your software, verify the success status of
the download as follows:
1 Log into the CoreBuilder 9000 LMA. See "Starting Up" on page 38 for
complete log in instructions.
2 Display the Software Download Status by entering the command, 1 3 1
at the Main Menu prompt.
3 Examine the system message and, if necessary, take action according to
Table 5.
Table 5 Download messages
Message
System is loading from ip address,
file. Received n%
Completed successfully
Unknown
Error while downloading
No response from server
Checksum error
Image is incompatible with the
device
Image file not found
System Loader cannot reach the
server
Flash memory partially erased
Meaning and Action
System loading
Download completed
No activity, nothing downloaded
CRC error, download again. If the
error persists, contact 3Com
technical support.
Bad connection
- check cable connection
- check if TFTP server is up
- check TFTP server IP address
Download again
The downloaded file properties [e.g.
name] does not match the internal
CB list of properties
Check if the file exists in the path
Check the following:
- cable connection
- if TFTP server is up
- TFTP server IP address
After downloading Switch Fabric
software: Download software again
via RS-232 port.
After downloading ATM Interface
Module software: Download
software again via TFTP.