8 Operating

8.4.4 Menu 4: "DLS/TLS setup"

Overview:
Search DLS/TLS ...
Text assignment
Main menu
TLS times
Test & status menu
3-PhW-Combinations
Block & reset alarms
Basic settings
The procedure is necessary, for example when the system is first
DLS/TLS Setup
commissioned or after adding/removing DLS or TLS mo-dules.
Circuit setup
All addresses are searched in succession for installed DLS and TLS
Luminaire setup
Logbooksetup
modules.
Send ServicePinMsg
The icon bar
Menu 4
Search DLS/TLS ...
Text assignment
TLS times
 Selection of
menu options
with the keys 
 <ok>:
confirm selec-
tion
 <Menu>: can-
cel and return
to the previous
menu (any
changes en-
tered are saved)
 <ESC>: cancel
Search DLS/TLS ...
and return to
Text assignment
the previous
TLS times
menu (any
3-PhW-Combinations
changes en-
tered are not
saved)
Notes:
 flashing input
You can use this menu to view assignments with external modules and
prompt
assign/edit module names without changing the configuration.
These module names are stored on the memory card and displayed in
the LCD display menus as operator help. Text assignments cannot be
made with the CU CG-S if a memory card is not inserted!
A more user-friendly input is possible using a CEAG configuration
software for the ZB-S system with a PC (data are transmitted by the
memory card).
Search DLS/TLS ...
Text assignment
TLS times
3-PhW-Combinations
Search DLS/TLS ...
Text assignment
TLS times
3-PhW-Combinations
88
Mounting and Operating Instructions CEAG Central Battery System ZB-S 40071860179 (L) November 2018 www.ceag.de
Menu 4.1:
Find address:
<ok>
Search result
indicates how the search is progressing.
Find address:
Search result
DLS+3Phase monit.
Menu=No
If no external bus module is found, you will
see the message
Search result
not installed
If a bus module has been identified, you will
see the message ...
Search result
DLS+3Phase monit.
Search result
DLS module external
Search result
TLS module external
Menu 4.2:
Text assignments
<ok>
DLS+3Phase monit. N
DLS/TLS Text
Menu 4.3:
TLS:N
o
 <ok>
Time
DLS/TLS Text
Menü 4.4:
3-Phase monitoring 12<>
<ok>
3-Phase monitoring 1 *
3-Phase monitoring 2
3-Phase monitoring 3
3-Phase monitoring 4
3-Phase monitoring 5
3-Phase monitoring 6
3-Phase monitoring 7
 <ok>: The search result is accepted; the
n
O
parameters will be used by the CU CG-S f
the controller
 <Menu>: The search result is rejected – th
old settings are retained
When all possible addresses have been
polled the procedure is closed and the sys
tem returns to menu 4 "DLS/TLS Setup"
with the new para meters.
 Finish and return to Menu 4 with
n
O
<Menu>
OK=YES
Line selection (line 2, 4) with 
Select a bus address with 
o
The message "DLS/TLS Text" appears on line 4
as a default setting or, if already defined, a mod
ule name
Editing DLS/TLS Text:
 Finish and return to Menu 4 with <Menu>
Line selection (line 1, 2) with 
Port:N
o
Make changes in the input field with
1 min
When this menu option is selected the system dis-
plays the first TLS module number it finds; in the
"Port" input field you can now select from among th
possible ports of the modules with 
In line 2 the stairwell light operation times 1 sec, 1 ..
15 min can be selected with
Line 3 shows the module name (s. menu 4.2).
 Finish and return to Menu 4 with <Menu>
After the search of the 3PhW and activate of the opti
of selective emergncy lighting, at DLS/TLS-Setup appe
the menu option „3-Phase monitoring combination. "
In the first row of this menu the current Phase mo
toring can be choosed which logic connected with oth
Phase monitorings if other 3-Phase monitorings rep
a mains failure.
From the second row appear a list of 3-Phase monitori
which can logic connected with the Phase monitori
of the first row.
By pushing the <ok> push button the favored Pha
monitoring will connected.
The connection is shown by the * sign.
Select line 4 with 
Select the input point with 
All the possible alphanumeric characters ar
displayed cyclically with the cursor keys .
Once a name has been fully entered, con-
firm the entry with <ok>. The remaining
characters after the current cursor position
are cleared.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents