Eaton CEAG CG-Controller Operating Instructions Manual
Eaton CEAG CG-Controller Operating Instructions Manual

Eaton CEAG CG-Controller Operating Instructions Manual

Controller for cg 2000/zb-s
Table of Contents

Advertisement

Quick Links

CEAG CG-Controller for CG 2000/ZB-S
Operating Instructions
Target group: Skilled electricians

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CEAG CG-Controller and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eaton CEAG CG-Controller

  • Page 1 CEAG CG-Controller for CG 2000/ZB-S Operating Instructions Target group: Skilled electricians...
  • Page 2: Table Of Contents

    Password ....24 devices ..... .15 Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 3 Logbook ..... 34 12.2.1 Layout of the logbook ..35 Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 4: Safety Instructions

    You must comply with the national stat- utes and directives governing inspection and safety tests (e.g. for function and duration tests). Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 5: Conformity With Standards

    «4.2 Use as prescribed». In particular, inspections and safety checks and their documentation must be carried out by specially authorised engineering personnel (in accordance with the national statutes and direc- tives). Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 6: Specifications

    The overlaying of different types of inter- • Hazards due to improper use of the device. ference increases the overall level of radiated noise, hence the need to protect all devices from electromagnetic interference (EMI). In Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 7 • unauthorised or inexpert modifications – to the connections and settings of the system, – or for programmingthe system, • operating proscribed or unsuitable devices or groups of devices. Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 8: Installation

    The device is designed for operation at 230 V AC or 24 V DC. Lines must be connected as shown in Figure 2. A(2) B(2) CG-S-Bus (2) Figure 3: Bus connection Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 9: Necessary Entries And First Steps

    The “Emergency lighting system” means the corresponding CG 2000 or ZB-S controller systems for the respective controller type. Figure 4: CG-Controller in the emergency lighting system Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 10: Definitions Of Keys

     • Increase value • Activate Table 1: Definitions of keys Alphanumeric keyboard LEDs for operation test fault LEDs for LCD display communication memory card Figure 5: Control panel Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 11: Status Display And Fault Display

    Line 3 of the Device info menu accor- displayed. If there are additional fault messages, ding to the same priority. you can display them in the submenu by pressing the ENTER key. Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 12 2) If a communication fault is detected on the CG-S bus with one or more devices, the device with the highest device address is always displayed as the fault. Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 13: Menus

    9 .2 .2 Cyclic data reception of emergency lighting systems The information from the emergency lighting systems is read cyclically. This information is required for the status and fault display, the relay and the logbook. Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 14 Dev. config. -> SD Dev. config. <- SD Text -> SD Text <- SD  Select menu item (Enter)  Cursor position lower Menu One menu level higher  Cursor position higher Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 15: Test" Menu

    Functiontest one dev Cancel  /  Selection in Line Durationtest all dev All devices 3: Cancel „no/yes“ Durationtest one dev  Exits the durationtest that Cancel durationtest ∕ is currently running Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 16: Block/Reset" Menu

    The manual reset is for backspace the system by hand (or at CGVision) into general operation-mode after a mains failure. This is needed at operational dimmed locations (f.e. cinemas, etc.) so that the sytem is not reset automatically. Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 17: Info Device" Menu (Submenu 1)

    Operation: Selection / display: Line SKU 1/7 circuit:1↔ Menu One menu level higher Circuit-status:  /  Selection in Line 1: Circuit failure Next/previous SKU or Circuit name circuit Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 18: Circuit Status Of Zb-S In Line 2

    During communication with the system, «Please wait...» is displayed. If there is an error, the faulty communication pro- cess is automatically repeated. The read process then lasts somewhat longer. Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 19: Luminaire Status (Device Type=Cg2000)

    – – – luminaire. Meanings of the icons:  lum. is turned off  lum. is turned on lum. is defective no lum. present (not programmed in the luminaire setup) Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 20: Dls/Tls/3Phw-Status (Device Type=Cg2000)

    «Communication failure» appears in Line 4. Selection (status display) Sample display Operation: Line Line Device status U=54 V I2=+0.1A Menu One menu level higher Failure reports T=21.8°C BT:00:00h Circuit-status Luminaire-status DLS/TLS/3PHW-status * Charging-/bat.stat.  Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 21: Setup Cg-Controller" Menu

    You can switch back to standard time by pressing the 9 key in the «Time and date» submenu item. The hour is decreased by 1. 9 key = WXYZ W = Standard time. Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 22: Next Ft

    13.08.02 at 14:15. If the CG-Controller happens to be out of operation, the emergency lighting systems will automatically per- form the next durationtest on 13.08.02 at 15:15 as a safety function. Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 23: Relay Settings

    The relay only gets activated at the end o fone polling round, that means after request of all status information. Because of that there could occur delays according to activation. The more systems are registered the longer takes one polling round. Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 24: Default Relay Setting

    9 .8 .8 .3 Activate submenu password Display: Operation: Line Enter password 0 ... 9 Password entry Activated  Accept Password (6 digits) Password 123456 To enter numbers, use the numeric keypad. Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 25: Menu Password Inquiry

    Sample display: Operation: Line CG-Controller Z720.A Customer service info. Menu One menu level higher Operate as master? Password  /  Select no/yes NID receive  Confirm selection Network Master Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 26: Setup Device" Menu

    Menu = cancel surching 9 .9 . 1 .4 «Device not found» message Display: Operation: Line Adr.=01 not found Menu Stop search Please wait... Menu = cancel surching Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 27: Device Autom

     Confirm selection After entering the NID and ENTER the device name is displayed in line 4. If the wrong NID has been entered, communication failure is displayed in line 4. Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 28: Synchronising Clocks

    Sample display: Operation: Line Luminaire failure DC Menu One menu higher Circuit:  Back 1..5..0..5..2 – – – – – – – – – – – – – – Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 29: Delete Logbook

    Operation: Display: Selection (submenu) Line Line Contr. config.←SD Display logbook Menu One menu level higher Delete logbook  /  Select yes/no All devices->SD  Confirm selection Contr. config.→SD Contr. config.<-SD ∕ Dev.config.-> SD Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 30: Saving The Device Configuration

    If a fault is detected while reading from the SD, the following message appears: Display Operation: Line Menu One menu level higher Dev. config.←SD  Confirm fault SD read fault Continue with  Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 31: Reading Texts From The Device And Saving To Sd (Text → Sd)

    The following message appears when no memory card is insert- ed in the CG 2000: Operation: Display Line Menu One menu level higher Text←SD  Confirm fault No SD in the device Continue with  Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 32: Cg-Controller Configuration

    All systems marked with 0x02 on the SD will be updated. Finally the CG-Controller sets 0x060 on 0xFF and the particular device status on 0x01. Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 33: Transfer Text To The Device

    Process cancelled  confirm Continue with  10 .3 . 1 .4 Ending the download (configXX, texteXX/CG 2000) Display: Line Operation:  confirm Process terminated Continue with  Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 34: Led Displays

    Mains failure of UV RS485 Mains failure of device RS485 transmission fault Battery failure Converter failure Charge-/isol. failure Luminaire failure Not enough capacity Battery operation CG-S bus communication failure Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 35: Layout Of The Logbook

    Data flow from the devices of an emergency lighting system to a PC via CG-Controller and SD The “Emergency lighting system” means the corresponding CG 2000 or ZB-S controller systems for the respective controller type. Manual CEAG CG-Controller for CG 2000/ZB-S 30080001458 (C) July 2016 www.ceag.de...
  • Page 36 At Eaton, we’re energized by the challenge of powering a world that demands more. With over 100 years experi- ence in electrical power management, we have the exper- tise to see beyond today. From groundbreaking products to turnkey design and engineering services, critical indus- tries around the globe count on Eaton.

Table of Contents