26
Assignment for connector 1:
Supply voltage and frequency output signal.
Connector
Device plug
6
1
5
7
2
3
4
Top view
1)
RS-422 complementary signals; with cable lengths exceeding 10 m, we recommend
using a termination resistor R = 120 ohms between the (wh) and (rd) wires.
2)
RS‐422: Pin 1 corresponds to A, Pin 4 corresponds to B.
NOTE
Torque flanges are only intended for operation with a DC supply voltage. They
must not be connected to older HBM amplifiers with square‐wave excitation.
This could destroy the connection board resistances or cause other faults in
the amplifiers.
HBM
Assignment
pin
Torque measurement signal
1
(frequency output; 5 V
Supply voltage 0 V;
2
Supply voltage 18 V  30 V
3
Torque measurement signal
4
(frequency output; 5 V
Measurement signal 0 V;
5
symmetrical
Shunt signal trigger 5 V  30 V
6
7
Shunt signal 0 V;
Shielding connected to housing ground
1),2)
)
1),2)
)
T40B
Wire
Sub‐D
color
connector
pin
wh
13
bk
5
bu
6
rd
12
gy
8
gn
14
gy
8