Testing The Drain Valve; Testing The Pump; Refitting The Pad Frames; Adjusting Cooler Settings - Seeley BREEZAIR EXVQ Installation Manual

Hide thumbs Also See for BREEZAIR EXVQ:
Table of Contents

Advertisement

COMMISSIONING
It is advisable to check the water level again after the float valve
washer has "bedded in".Once the water level is correct, isolate
the control box and connect the pump plug.
EXVQ MODEL
13/64"
(5mm)

TESTING THE DRAIN VALVE

Select the "SETTINGS" mode on the MagIQtouch Controller
and select the "COOLER" sub-heading. Select the "MANUAL
DRAIN" option to operate and test the drain valve.

TESTING THE PUMP

Test the pump by turning the cooler on at the MagIQtouch
controller, in "COOL" mode. Check that water is evenly
distributed to all pads.
Note! If the cooler has not been on before it will run a "Pre-Wet"
routine where the pump will operate to saturate the pads.
This cycle takes 2 minutes, then the fan will start automatically.

REFITTING THE PAD FRAMES

Refit the pad frames by locating the bottom edge in the pan
(Reservoir) groove, then push the top in under the lid.
Refit the corner clips after replacing the pad frame(s).
2
1
|
14

ADJUSTING COOLER SETTINGS

Within the SETTINGS menu of the MagIQtouch Controller is the
COOLER sub-heading. Here various settings of the cooler can
be adjusted.
ILL526-D
About Appliance
Displays information such as model number, serial number and
software version for all coolers connected to the controller.
Min/Max Set Temperature
ILL526-D
Defines the maximum and minimum temperature values.
Night Quiet Mode
Restricts fan speed to a specified level during a specified
period.
Humidity Control (when Internal Air sensor is connected)
Set desired humidity levels.
External Air Sensor
Not fitted on EXVQ models.
ILL1838-B
Manual Drain
Turns cooler off and drains the pan (reservoir).
Pad Flush
Turns cooler off and runs pump for a specified amount of time.
Drain And Dry
Cooler will drain and fan will run for 1 hour every day at a
specified time.
Water Manager
Select the preferred water management method:
• Salinity Measurement - replaces water when Salinity level
reaches set point.
• Timed Drain - drains pan (reservoir) After 8 pan fill cycles or
every 1-2 hours (system dependant).
• No Drain Control - salinity control external to electronics
eg. continuous bleed.
• No Water Thermostatic - allows Thermostatic control in VENT
mode. No water present. Cooling performance is limited.
Weatherseal Open Speed
The cooler fan will turn on at the specified Weatherseal opening
speed for the first 10 seconds each time it starts up. It will then
3
return to the set fan speed.
Prewet
When COOL mode is activated, the pump will run for 90
seconds before the fan is switched on.
Salinity Level
ILL1600-A
Sets the salinity level at which the pan (reservoir) will drain in
"SALINITY MEASUREMENT" mode.
Pan (Tank) Drain Delay
Sets the time delay before the drain valve opens after the pump
in the cooler is turned off.
AutoClean
Select the preferred cleaning interval (50 / 100 / 200 hours).
At 8.00am after the selected running hours has been reached,
the cooler will drain the pan (reservoir), fill with fresh water and
operate the pump for 5 minutes. When complete, drains the pan
and returns to previous operation mode.
ILL1664-A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents