INSTALLING THE DRAIN VALVE

Water drained from the cooler must be carried away to a
suitable discharge point in accordance with local regulations.
Important! Never drain water from the cooler directly on to the
roof. Assemble the drain valve (1) as shown:
ILL2112-A
Make sure the "O"-ring (2) is fitted before placing the drain valve
into the hole. Screw the nut (3) up tightly by hand underneath
to locate the drain valve. Locate the funnel (4) up against the
bottom of the drain valve thread and secure with the second,
larger nut (5). Make sure that you use the correct drain adaptor.
Make sure the drain water discharge flows freely away from the
cooler. Important! Do not over-tighten plastic fittings.

INSTALLING THE WATER SENSOR

Assemble the water sensor as shown by clipping the sensor to
the tank. Ensure that the clip fully engages.
Route the sensor cable through the cable supports in the tank
as shown and leave the end clear of any water. The cable will
be plugged in later.
|
10
INTERNATIONAL

BLEED FUNNEL

(Standard for CPQ & BMQ models, optional for LCQ, LCS,
LCQI, TBQ, TBS, TBQI & TBSI models)
The bleed funnel reduces the accumulation of salts and
minerals in the cooler. It also acts as an overflow and a drain.
ILL746-F
Assemble the bleed funnel as shown.
Make sure the bleed funnel is correctly oriented and that the
o-rings are fitted before placing it into the hole. Screw the nut up
tightly by hand underneath the cooler.
Make sure that you use the correct drain adaptor. Drain-
water from the bleed funnel must be carried away to a suitable
discharge point on the building or property in accordance with
local regulations. Do not drain directly onto the roof surface.
The bleed rate required will vary according to water quality,
but should initially be set to the minimum rate as set out in the
table.
Push the remaining plugs into the blind holes provided. In poor
quality water areas where the salt and mineral contents are
high, adjust the bleed rate by inserting one or more extra plugs
than specified in the table.
Note! If the water sensor is fitted, you will need to disconnect
it from the Electronics Module and remove it from the cooler
completely. Then fit the shorting plug (supplied in the Bleed kit)
to the socket where the water sensor was fitted (refer Electrical
Connection section).
LCQ250, LCQ350, LCS280, LCS380,
LCQI250, LCQI350, BMQ500,
BMQ750, CPQ450, CPQ700
ILL1056-C
Cooler Models
1 Plug in
LCQ450, LCQ550, LCS480, LCS580,
LCQI450, LCQI550, BMQ900,
BMQ1150, CPQ850, CPQ1100,
TBS500, TBQ550, TBS580, TBQI550,
ILL970-C
2 Plugs in
TBSI580,