Using The Cooler; Air Too Cold; Air Not Cold Enough; Drain Valve & Bleed System - Seeley Braemar Сoolair LCB250 Owner's Manual

Evaporative cooler
Hide thumbs Also See for Braemar Сoolair LCB250:
Table of Contents

Advertisement

WALL CONTROL FUNCTIONS
cont.

USING THE COOLER

Now that you have read these instructions,
press the
button to turn your air cooler
on. If the air cooler has not operated for a
while, "Pre Cool Cycle" will flash on the display.
The "Pre Cool Cycle will begin and will take
only a few minutes to complete. After this time,
the fan will come on automatically, and you can
enjoy the comfort of cool fresh air!

AIR TOO COLD

With the cooler running in Automatic mode,
you may find that you are too cold or that the
air cooler is blowing too much air. Press
to lower the automatic temperature setting and
reduce the amount of cooling.
If you are too cold with the cooler running in
Manual mode, then press
the fan speed. You can also circulate fresh
un-cooled air by pressing COOL until "Vent"
displays.

AIR NOT COLD ENOUGH

You may find that with the air cooler running
in Automatic mode, you are not cool enough.
Simply press
to increase the cooling
rate.
If you are not cool enough with the air cooler
running in Manual mode, then press
increase the fan speed. Ensure that cooled air
is circulating by pressing
displays.
You can experiment with the settings on your
wall control. This is the best way to get the
most from your air cooler.
|
8
to reduce
to
until "Cool"
LCB/CPS/BM Evaporative Cooler
DRAIN VALVE & BLEED
SYSTEM
This cooler comes with a continuous bleed
system (Coolair CPL, Coolair CPS, Braemar
BM) or automatic Drain Valve (standard for
Braemar LCB, optional for CPL, CPS and BM).

CONTINUOUS BLEED SYSTEM

During operation, the bleed system will
drain small amounts of water. This ensures
fresh water is continually added to dilute salt
accumulation in the water caused through
evaporation. This helps keep the air cooler
in good condition and ensure optimum
performance. The bleed rate will depend on
local operating conditions and will be set by the
installer.

AUTOMATIC DRAIN VALVE

If the drain valve was installed instead of the
continuous bleed system then your cooler will
automatically drain periodically. This ensures
the water is always fresh and helps maintain
your cooler in good condition to ensure
optimum cooling performance. The frequency
of the automatic drain may have been adjusted
by your installer according to the general water
quality in your area.
When the cooler is turned off for 72 hours,
the drain valve will open automatically and
empty water from the cooler. When the cooler
is turned on again, fan operation will delay for
a few minutes while the tank refills and the
cooling pads are saturated again.
At any time when the thermostat is OFF, you
can drain the cooler by pressing and holding
and
for 1 second. The display
will show "dr" to confirm the operation has
activated.
ILL1478-A