INSTALLING THE FLOAT VALVE

Assemble the float valve to the cooler as shown.
Ensure all washers and (O-rings are in place. No thread tape is
required. Do not over-tighten the plastic fittings.
Make sure the float is centrally positioned and up and down
movement is unrestricted.
CTA Models

MAINS WATER CONNECTION

Connect the main water supply to the water inlet point under
the cooler using the 1/2" Nut and olive fitting or 1/2" - 1/4" brass
compression adaptor fitting as required.
Always install a shut-off valve (do not use a non-return type
valve) close by the air cooler.

BLEED FUNNEL

The bleed funnel reduces the accumulation of salts and
minerals in the cooler. It also acts as an overflow and a drain.
Assemble the bleed funnel as shown.
ILL985-E
Make sure the bleed funnel is correctly oriented and that the
O-rings are fitted before placing it into the hole. Screw the nut
up tightly by hand underneath the cooler.
Make sure that you use the correct drain adaptor. Drain-
water from the bleed funnel must be carried away to a suitable
discharge point on the building or property in accordance with
local regulations. Do not drain directly onto the roof surface.
The bleed rate required will vary according to water quality,
but should initially be set to the minimum rate as set out in the
table.
Push the remaining plugs into the blind holes provided. In poor
quality water areas where the salt and mineral contents are
high, adjust the bleed rate by inserting one or more extra plugs
than specified in the table.
Note! In some locations due to regulatory requirements, the
use of bleed funnels are not allowed. In these locations ensure
the plugs are not inserted or are removed from the bleed funnel
entirely.