Horizon Fitness QC-S300 Manual page 68

Table top collator
Hide thumbs Also See for QC-S300:
Table of Contents

Advertisement

How to Install the CT-S30 Delivery Unit for the Side Stapling
(4) Remove the covers on both sides by removing the
two upper screws and loosening the lower two
screws.
(5) Adjust the angle of the lower delivery guide so
that the gap between the lower delivery guide and
the jog guide is 1 to 2 mm (0.04 to 0.08").
• Loosen the mounting screws under the lower delivery
guide so you can adjust the angle of the guide. After
making the adjustment, lock the position of the lower
delivery guide by tightening the two screws.
(6) Adjust the angle of the upper delivery guide so
that the gap between the upper delivery guide and
the lower delivery guide is 5 mm (0.2").
• Loosen the mounting screws above the upper delivery
guide to adjust the angle of the guide. After making
the adjustment, lock the position of the upper delivery
guide by tightening the two screws.
(7) Install the covers on both sides using four screws.
3.
Connect the power cord for the CT-S30
to the collator.
63
Lower Delivery Guide
Jog Guide
1 to 2 mm
Mounting Screw
(0.04" to 0.08")
Upper Delivery
Mounting Screw
Guide
5 mm (0.2")
Lower Delivery Guide
Power Cord
2109650301E1
21096 50301F1
2109650301G1
2109650301E1
CT-S30
2109650301H1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qc-s300f

Table of Contents