6.6 Symptoms

If your product does not work as expected, follow the symptoms guide below.
There is a FAQ (Frequently Asked Questions) on www.husqvarna.com which provides more detailed
answers to a number of standard questions. Contact your local Husqvarna representative if you still
cannot find the reason for the fault.
Symptoms
Cause
The product has
The boundary wire is not laid in a long
difficulty docking.
straight line that is far enough out from
the charging station.
The charging station is on a slope.
The product runs
The product clock needs to be set.
at the wrong time
The start and stop times for mowing
are incorrect.
The product vi-
Damaged blades lead to imbalance in
brates.
the cutting system.
Too many blades in the same position
lead to imbalance in the cutting system.
Different versions (thickness) of Husq-
varna blades are used.
The product runs,
The product searches for the charging
but the blade disc
station.
does not rotate.
The product mows
Grass or other foreign object blocks the
for shorter periods
blade disc.
than usual be-
tween charges.
The battery is spent.
Both the mowing
The battery is spent.
and charging times
are shorter than
usual.
The product is
The product is parked due to a timer
parked for hours in
setting, or because
notice has been chosen in the app.
the charging sta-
tion.
1230 - 001 -
Action
Check that the charging station has
been installed correctly. Refer to
stall the charging station on page 20
Place the charging station on a surface
that is entirely level. Refer to
ine where to put the charging station on
page 16 .
Set the clock. Refer to
& date on page 31 .
Reset the start time and stop time set-
tings for mowing. Refer to
timer setting on page 25 .
Inspect the blades and screws and re-
place them if necessary. Refer to
place the blades on page 38 .
Check that only one blade is fitted at
each screw.
Check if the blades are of different ver-
sions.
No action. The blade disc does not ro-
tate when the product is searching for
the charging station.
Remove and clean the blade disc. Re-
fer to
37 .
Replace the battery. Refer to
move the battery on page 53 .
Replace the battery. Refer to
move the battery on page 53 .
Edit the timer settings or press the
Park until further
START button to start the product.
To exam-
To set the time
To reset the
Chassis and blade disc on page
To re-
To re-
Troubleshooting - 49
To in-
Re-

Hide quick links: