Jetter AG
This module lets you assign a value range to each counter. The module
JX3-CNT checks whether the count value is within the limits of this range.
[digits]
32767
-32768
Number
1
Upper limit, MR 1y09
2
Lower limit, MR 1y08
3
Count value (in steps) of the corresponding input.
For configuring the monitoring of limit values, the following module registers
are used:
Registers
MR 0
Module state
MR 1y00
Status of counter y (y = 5 ... 9)
MR 1y08
Lower limit
MR 1y09
Upper limit
t [s]
Description