Environmental Conditions; Emi Values; Tab. 5 Environmental Conditions; Tab. 6 Pulses Iso 7637-2 - Jetter JXM-IO-E31 User Manual

Expansion module
Hide thumbs Also See for JXM-IO-E31:
Table of Contents

Advertisement

Jetter AG

4.4 Environmental conditions

4.5 EMI values

Pulses ISO 7637-2
Irradiation
ISO 11452
Emission CISPR 25
ESD EN 61000-4-2
User Manual – JXM-IO-E31
Parameter
Operating temperature
Storage temperature
Relative humidity
Weather resistance
Salt water resistance
Degree of protection
Without mating connector IP23
with mating connector
Tab. 5: Environmental conditions
The device has E1 approval according to ECE R10 Rev. 5 and CE conformity
according to ISO 14982.
Test pulse
1
2 a
2b
3 a
3b
4
5b
Tab. 6: Pulses ISO 7637-2
Parameter
Protection against RF
noise
Tab. 7: Irradiation ISO 11452
Parameter
Narrowband emission
Wideband emission
Tab. 8: Emission CISPR 25
ESD EN 61000-4-2
Contact discharge
Discharge through air
Tab. 9: ESD EN 61000-4-2
Description
-40 °C ... +85 °C
-40 °C ... +85 °C
5 % ... 95 %
The device is designed for use in all weather condi-
tions and is suitable for outdoor use.
The device is not designed for maritime applications.
IP66
Values
-450 V
+37 V
+20 V
-150 V
+150 V
Ua1: -6 V / 50 ms
Ua2: -4 V / 500 ms
Load dump
70 V / 2 Ω / 350 ms
Description
20 MHz ... 2 GHz 100 V/
m
Values
30 MHz ... 1,000 MHz
30 MHz ... 1,000 MHz
Values
±4 kV
±8 kV
Technical specifications | 4
Standards
ISO 16750-4
ISO 20653:2013
Functional class
C
B
C
A
A
B (12 V systems)
A
Functional class
B
Min. 1 dB below limit
Min. 1 dB below limit
Functional class
A
A
13 / 68