Emi Values; Tab. 5 Pulses Iso 7637-2; Tab. 6 Irradiation Iso 11452; Tab. 7: Emission Cispr 25 - Jetter JXM-IO-E32 User Manual

Expansion module
Hide thumbs Also See for JXM-IO-E32:
Table of Contents

Advertisement

Jetter AG

4.5 EMI values

Pulses ISO 7637-2
Irradiation
ISO 11452
Emission CISPR 25
ESD EN 61000-4-2
User Manual – JXM-IO-E32
The device has E1 approval according to ECE R10 Rev. 5 and CE conformity ac-
cording to ISO 14982.
Test pulse
1
2 a
2b
3 a
3b
4
5b
Tab. 5: Pulses ISO 7637-2
Parameter
Protection against RF
noise
Tab. 6: Irradiation ISO 11452
Parameter
Narrowband emission
Wideband emission
Tab. 7: Emission CISPR 25
Parameter
Contact discharge
Discharge through air
Tab. 8: ESD EN 61000-4-2
Values
-450 V
+37 V
+20 V
-150 V
+150 V
Ua1: -12 V / 50 ms
Ua2: -5 V / 500 ms
Load dump
70 V / 2 Ω / 350 ms
Values
20 MHz ... 2 GHz 100 V/
m
20 MHz ... 2 GHz 30 V/m A
Values
30 MHz ... 1,000 MHz
30 MHz ... 1,000 MHz
Values
±4 kV
±8 kV
Technical specifications | 4
Functional class
C
B
C
A
A
B (24 V systems)
C
Functional class
B
Min. 1 dB below limit
Min. 1 dB below limit
Functional class
A
A
13 / 55