Emc Values; Tab. 6 Pulses To Iso 7637-2; Tab. 7 Pulses To Iso 16750-2; Tab. 8 Irradiation To Iso 11452 - Jetter JXM-IO-E30 User Manual

Expansion module
Hide thumbs Also See for JXM-IO-E30:
Table of Contents

Advertisement

Jetter AG

4.5 EMC values

Pulses to ISO
7637-2
Pulses to ISO
16750-2
Irradiation to ISO
11452
Emission to CISPR
25
ESD EN 61000-4-2
JXM-IO-E30 User Manual
The device has E1 approval according to ECE R10 Rev. 5 and CE conformity
according to ISO 14982.
In addition, the device has CE conformity according to EN 61000-6-1 and EN
61000-6-2 in the industrial sector as of hardware revision 02. In order to fulfill the
criteria for CE conformity, additional measures are necessary
in the industrial sector
Test pulse
1
2a
2b
3a
3b
Tab. 6: Pulses to ISO 7637-2
Test pulse
4
4
5b
Tab. 7: Pulses to ISO 16750-2
Parameter
Protection against RF
noise
Tab. 8: Irradiation to ISO 11452
Parameter
Narrowband emission
Wideband emission
Tab. 9: Emission to CISPR 25
ESD EN 61000-4-2
Contact discharge
Discharge through air
Tab. 10: ESD EN 61000-4-2
[} 26]).
Values
-450 V
+37 V
+20 V
-150 V
+150 V
Values
Ua1: -12 V / 50 ms
Ua2: -5 V / 500 ms
Load dump
70 V / 2 Ω / 350 ms
Values
20 MHz ... 2 GHz 60 V/m A
20 MHz ... 2 GHz 75 V/m B
20 MHz ... 57 MHz and
82 MHz ... 2 GHz
100 V/m
Values
30 MHz ... 1000 MHz
30 MHz ... 1000 MHz
Values
±4 kV
±8 kV
Technical specifications | 4
(Measures for use
Functional class
C
B
C
A
A
Functional class
B (24 V systems)
C (12 V systems, E1)
C
Functional class
B
Min. 1 dB below limit
Min. 1 dB below limit
Functional class
A
A
13 / 62