Jetter JX3-PS1 User Manual
Hide thumbs Also See for JX3-PS1:

Advertisement

Quick Links

User Manual
JX3-PS1
We automate your success.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JX3-PS1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Jetter JX3-PS1

  • Page 1 User Manual JX3-PS1 We automate your success.
  • Page 2 Revisions and further development of our products are not automatically mentioned in a reviewed document. Jetter AG shall not be liable for errors in form or content, or for missing updates, as well as for damages or disadvantages resulting from such failure.
  • Page 3: Table Of Contents

    Dismounting the enclosure from the backplane module ............ 17 6 Electrical connection ........................ 18 Improving the noise immunity.................... 19 Ports and interfaces ...................... 20 6.2.1 Terminal X10 - Power supply .................. 20 6.2.1.1 2-pin connector, spring-cage technology............ 20 Functional test ........................ 20 JX3-PS1 User Manual...
  • Page 4 Table of contents Jetter AG 7 Maintenance and repairs ...................... 21 Maintenance, repairs and disposal.................. 21 Storage and shipment ...................... 21 8 Service ............................ 22 Customer service ........................ 22 9 Spare parts and accessories ....................... 23 Spare parts.......................... 23 Accessories ...........................  23 JX3-PS1 User Manual...
  • Page 5: Introduction

    For information on new revisions of this document, visit the download area on our website. This document is not subject to any updating service. Start | Jetter - We automate your success. For further information refer to the following information products: ■...
  • Page 6: Safety

    Machinery Directive This device is no safety-related part as per Machinery Directive 2006/42/EC, and must, therefore, not be used for safety-relevant applications. This device is NOT intended for the purpose of personal safety, and must, therefore, not be used to protect persons. JX3-PS1 User Manual 6 / 24...
  • Page 7: Warnings Used In This Document

    Low risk CAUTION Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. Material damage NOTICE Indicates a situation which, if not avoided, could result in malfunctions or material damage. JX3-PS1 User Manual 7 / 24...
  • Page 8: Product Description

    Product description | 3 3 Product description The JX3-PS1 is an expansion module and provides power supply of up to 8 expansion modules. The module is required if the power supply of the bus node or controller used is not sufficient to supply all connected expansion modules.
  • Page 9: Position And Amount Of Expansion Modules In The System

    INFO Further information For further information on this topic, refer to chapter Register and I/O Numbering of the JX3 Station in the Application-oriented Manual JX3 System in the down- load area of our homepage. JX3-PS1 User Manual 9 / 24...
  • Page 10: Status Indication

    Serial number Certification mark Item number Hardware revision Item name 3.6 Scope of delivery Scope of delivery Item number Quantity JX3-PS1 10000635 Male connector in spring-cage technology, 60870409 2-pin Terminal labels 60870411 Installation manual 60871940 JX3-PS1 User Manual 10 / 24...
  • Page 11: Technical Specifications

    Jetter AG Technical specifications | 4 4 Technical specifications This chapter contains information on electrical and mechanical data, as well as on operating data of the JX3-PS1. 4.1 Dimensions Fig. 5: Dimensions in mm 4.2 Mechanical specifications Category Description Standards Weight...
  • Page 12: Electrical Properties

    Corrosion immunity and No special protection against corrosion. Ambient air chemical resistance must be free from higher concentrations of acids, al- caline solutions, corrosive agents, salts, metal va- pors, and other corrosive or electroconductive con- taminants. JX3-PS1 User Manual 12 / 24...
  • Page 13: Emc Values

    Criterion A Discharge through air: 8 kV DIN EN 61131-2 Test peak voltage 8 kV DIN EN 61000-6-2 DIN EN 61000-4-2 Discharge through air 4 kV Test peak voltage Criterion A Tab. 7: Immunity to interference JX3-PS1 User Manual 13 / 24...
  • Page 14: Dc Power Supply Inputs And Outputs

    0.5 kV DIN EN 61000-4-5 Surge voltages, asymmetric, line to earth Common-mode interfer- tr/th 1.2/50 µs DIN EN 61131-2 ence DIN EN 61000-6-2 0.5 kV DIN EN 61000-4-5 Tab. 9: DC power supply inputs and outputs JX3-PS1 User Manual 14 / 24...
  • Page 15: Mechanical Installation

    Jetter AG Mechanical installation | 5 5 Mechanical installation This chapter describes how to install and replace the JX3-PS1. 5.1 Installing the device on the DIN rail Functional impairment caused by unfavorable installation NOTICE ► Install the device only in vertical position on the DIN rail (DIN EN 60715).
  • Page 16: Removing The Device From The Din Rail

    DIN rail release latch Detail view Disconnect the system from the power supply. Remove the device from the mains. Pry the release latch (2) downwards and pull the device off the DIN rail (1). JX3-PS1 User Manual 16 / 24...
  • Page 17: Dismounting The Enclosure From The Backplane Module

    Fig. 8: Dismounting the enclosure from the backplane module DIN rail latch Detail view Disconnect the system from the power supply. Press the upper and lower latches (1) on the device simultaneously. Keep the latches pressed and pull off the enclosure. JX3-PS1 User Manual 17 / 24...
  • Page 18: Electrical Connection

    Damages to material or functional impairment NOTICE Improper implementation of the wiring harness may cause mechanical stress. ► Protect the cables from bending, twisting or chafing. ► Install strain reliefs for the connecting cables. JX3-PS1 User Manual 18 / 24...
  • Page 19: Improving The Noise Immunity

    Note 016 EMC-Compatible Installation of Electric Cabinets on our homepage. DIN rail ■ Mount the JX3-PS1 on a DIN rail to DIN EN 60715 with the dimensions 35 x 7.5 mm. ■ The DIN rail must be electrically conducting and grounded by either of the two ways: ■...
  • Page 20: Ports And Interfaces

    The expansion modules to be supplied with power are connected to the right of the JX3-PS1 module. ► Power up the JX3 station. ð The LED R of the JX3-PS1 lights up green if the commissioning has been carried out correctly. JX3-PS1 User Manual 20 / 24...
  • Page 21: Maintenance And Repairs

    In case of damaged packaging inspect the device for any visible damage, and in- form your freight forwarder and the Jetter AG of the damage caused during ship- ment. If the device is damaged or has been dropped, it is strictly forbidden to use...
  • Page 22: Service

    To contact them, please call our technical hotline or use the contact form on our homepage: Technical hotline | Jetter - We automate your success. You are also welcome to send an e-mail to our technical hotline: hotline@jetter.de...
  • Page 23: Spare Parts And Accessories

    Male connector in spring-cage technology, 2-pin 60870409 Tab. 11: Spare parts 9.2 Accessories INFO The accessories are not part of the scope of delivery. Apt accessories can be obtained from Jetter AG. Component Item number Screwdriver 60871712 End clamp for DIN rail 60863970 Tab. 12: Accessories...
  • Page 24 Jetter AG Graeterstrasse 2 71642 Ludwigsburg www.jetter.de E-mail info@jetter.de Phone +49 7141 2550-0 We automate your success.