3. ADD-ON MODULES

3.1. Security relay

www.behnke-online.de
myintercom Plus IP video door intercom Instructions
This module provides further security meas-
ures by moving the door opener and the two
relays into the protected interior of the house
or building.
The security relay is connected to the door
station by four wires and is also supplied with
power through these.
Connect the following door station terminals
with the terminals of the security relay:
Markings on the
door station
SR-
SR+
TXD
RXD
NO (make contact), rating 30 VDC
max. 1 A
Floating contact, separate power supply
required for the connected device.
Add-on modules
Markings on the
security relay
SR-
SR+
TXD
RXD