Settings; Dip Switch Settings - Mastervolt CombiMaster 12V/2000W 100A User And Installation Manual

Inverter charger combination with ac–in support
Table of Contents

Advertisement

5 SETTINGS

Adjustment of the settings of the CombiMaster Inverter/Charger can be made in two different ways:
• By means of DIP switches.
• From a laptop connected to the CombiMaster Inverter/Charger via a USB Interface. Some settings,
like the AC IN Limit setting for example, can only be changed in this way.
CAUTION!
Invalid settings of the CombiMaster Inverter/Charger can cause serious damage to your
batteries and/or the connected load! Adjustment of settings must be carried out by authorized
personnel only.
5.1

DIP switch settings

Use a small screwdriver to carefully set the required settings.
Figure 4. DIP switches (factory settings)
In a CZone network:
DIP switch 1 must always be set to the
DIP switch 2 must always be set to the
DIP switches 3 to 10 must match the unique address used in the CZone network; the dipswitch (see the
CZone Configuration Tool Instructions manual).
In a MasterBus network:
DIP switch 1 must always be set to the
DIP switch 2 is MasterBus Powering
DIP switches 3 to 5 are used for battery type selection:
DIP switch
MasterBus settings (Flooded)
Flooded (fixed)
AGM (fixed)
Constant voltage (13,25V)
The following table lists the settings for DIP switches 6 to 9.
Inverter frequency 60Hz
Inverter frequency 50Hz
AC input support mode off
AC input support mode on
AC voltage input window wide
AC voltage input window narrow
Energy saving mode off
Energy saving mode on
CombiMaster 120V Series – User and Installation Manual
DIP switch 1 = CZone network (0) or MasterBus network (1).
DIP switch 2 = MasterBus powering off (0) or on (1)
DIP switches 3 to 10 are either used as CZone address or for
MasterBus battery and 3
OFF
OFF
position (1 ).
ON
(1 ) or
ON
3
4
1
0
0
0
0
0
1
Gel (fixed)
0
1
MLI (fixed)
1
0
2
1
1
DIP switch 6 7 8 9
0
1
0
1
rd
output settings.
position (0 ).
position (0 ).
(0 ). By default, this is
OFF
5
1
0
If all DIP switches are in the
(0 ), the settings suit a Flooded battery
1
0
but can be changed in MasterAdjust.
1
2
Constant voltage has no temperature
0
compensation.
1
0
1
0
1
19
.
OFF
position
OFF