  • Page 1 USERS MANUAL MASS SINE 12/1200-230V; 24/1500-230V; 12/2000-230V & 120V; 24/2500-230V & 120V SINE WAVE INVERTER...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS TABLE OF CONTENTS: v 4.0 June 2010 GENERAL INFORMATION.............................. 4 Use of this manual.............................. 4 Guarantee specifications ............................ 4 Validity of this manual ............................4 Quality ................................4 Liability ................................4 Identification label............................... 4 Changes to the Mass Sine ..........................4 SAFETY GUIDELINES AND MEASURES ........................
  • Page 3: General Information

    Changes to the Mass Sine may be carried out only after Mass Sine 12/2000-120V 25012000 obtaining the written permission of Mastervolt. Mass Sine 24/2500-120V 25022500 Copyright © 2010 Mastervolt / June 2010 / Mass Sine C2 & C3 / EN...
  • Page 4: Safety Guidelines And Measures

    Defects such as loose connections, burned cables etc. must be corrected immediately. • Do not touch the equipment when wet or if your hands are clammy. EN / Mass Sine C2 & C3 / June 2010 / Copyright © 2010 Mastervolt...
  • Page 5: Warning Regarding Life Support Applications

    Avoid short circuiting batteries, as this may result in explosion and fire hazard. Installation of the batteries and adjustments of the Mass Sine should only be undertaken by authorised personnel! Copyright © 2010 Mastervolt / June 2010 / Mass Sine C2 & C3 / EN...
  • Page 6: Operation

    Figure 2: Indicators and main swith Input voltage 12 Volt 24 Volt Shut off voltage 10V ±0.5V 19V ±0.5V Restart voltage 11V ±0.5V 22V ±0.5V EN / Mass Sine C2 & C3 / June 2010 / Copyright © 2010 Mastervolt...
  • Page 7: Remote Controlled Operation

    If the failure LED is lit you can check the nature of the failure on the inverter front. Refer to the applicable user’s manual for operation of the other remote control panels or interfaces Copyright © 2010 Mastervolt / June 2010 / Mass Sine C2 & C3 / EN...
  • Page 8: Installation

    Recommended torques AC wiring: Model Mass Sine Recommended torque AC wiring: In-Lbs All models: 1.5 – 1.8 Nm 13 – 16 In-Lbs EN / Mass Sine C2 & C3 / June 2010 / Copyright © 2010 Mastervolt...
  • Page 9: Dc Wiring

    With the MasterBus – Inverter interface you can connect your Mass Sine to the MasterBus network: a fully decentralized data network for communication between the different Mastervolt system devices such as the Copyright © 2010 Mastervolt / June 2010 / Mass Sine C2 & C3 / EN...
  • Page 10: Things You Need

    Tools to fix the screws / bolts with plugs to mount the cabinet to a surface • Philips screw driver to open the connection area of the Mass Sine EN / Mass Sine C2 & C3 / June 2010 / Copyright © 2010 Mastervolt...
  • Page 11: Installation Drawing

    This schematic is to illustrate the general placement of the Mass Sine in a circuit. It is not meant to provide detailed wiring instructions for any particular electrical installation. Figure 3: Installation drawing of the Mass Sine inverter Copyright © 2010 Mastervolt / June 2010 / Mass Sine C2 & C3 / EN...
  • Page 12: Installation Step-By-Step

    Slide the front cover plate from the cabinet Step 1 Continue with sections 4.9 and 4.10. Step 2 EN / Mass Sine C2 & C3 / June 2010 / Copyright © 2010 Mastervolt...
  • Page 13: Settings

    Sine. To reinstall the Mass Sine, follow the instructions as described in this chapter (chapter 4). Tighten all cable glands to ensure the pull relief Copyright © 2010 Mastervolt / June 2010 / Mass Sine C2 & C3 / EN...
  • Page 14: Trouble Shooting

    5 TROUBLE SHOOTING If you cannot solve a problem with the aid of this table, contact your local Mastervolt Service Centre. Make sure you have the following information present if you have to contact your local Mastervolt Service Center to solve a problem: Article and serial number (see section 1.6)
  • Page 15: Technical Data

    Mix of conventional and forced air cooling, by DC fans with variable speed. Enclosure Type Dimensions hxwxd in mm 340x261x130 420x318x130 420x318x130 Weight 6kg / 13Lbs 9.7kg / 21Lbs 9.7kg / 21Lbs Copyright © 2010 Mastervolt / June 2010 / Mass Sine C2 & C3 / EN...
  • Page 16: Specifications 24V Models

    Mix of conventional and forced air cooling, by DC fans with variable speed. Enclosure Type Dimensions hxwxd in mm 340x261x130 420x318x130 420x318x130 Weight 6kg / 13Lbs 9.7kg / 21Lbs 9.7kg / 21Lbs EN / Mass Sine C2 & C3 / June 2010 / Copyright © 2010 Mastervolt...
  • Page 17: Dimensions

    Figure 4: Dimensions Mass Sine 12/1200 - 230V and 24/1500 - 230V Figure 5: Dimensions Mass Sine 12/2000, 24/2500, 230V / 50Hz and Mass Sine 12/2000, 24/2500 117V 60Hz Copyright © 2010 Mastervolt / June 2010 / Mass Sine C2 & C3 / EN...
  • Page 18: Ec Declaration Of Conformity

    7 EC DECLARATION OF CONFORMITY Manufacturer Mastervolt Address Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Declare under our sole responsibility that Product: 24011200 Mass Sine 12/1200-230V 24021500 Mass Sine 24/1500-230V 24012000 Mass Sine 12/2000-230V 24022500 Mass Sine 24/2500-230V 25012000 Mass Sine 12/2000-120V 25022500...