System Not Programmed Correctly – PROGRAM SETTINGS
In some cases, the 5900e may not be programmed correctly, try to verify the correct programming.

Brine Tank Not Filling With Enough Water

Sometimes if the brine tank is not filling adequately, it is possible that the float assembly in the tank is set too
low. You would want the float to be several inches above the air check valve inside the tank. This will allow
for enough water to be added to the tank before shutting the brine fill cycle. If necessary, pull the float
assembly rod up to the appropriate height, and cut the rod at that height, leaving while keeping the rubber
washers the adequate space to hold the float in place.

Error Codes

There are five (5) error codes that could indicate a possible problem with the control valve:
Error 2 - Homing slot expected. Valve will start looking for home.
(Normal operation continues)
Error 3 - Encoder is not sending a signal
(Valve requires service to continue)
Error 4 - Unable to find homing slot
(Valve requires service to continue)
Error 5 - Motor overload (stalled position or shorted motor)
(Valve requires service to continue)
-New Signature program is identified by "r2.1" in presentation upon power up.

What To Do If Your Filter Tank Does Not Sit Level On the Floor

Your black filter tank base is not glued to the bottom of your tank. Occasionally tank bases will
become crooked during shipment. If you find that that your tank does not sit level on the floor, you
can easily adjust it by holding the empty tank and rapping it on a concrete or solid floor once or
twice in order to level it.
Page 21
Tannin 5900e Installation & Startup Guide
www.cleanwaterstore.com
Rev 062915