Maintenance
Add 1 cup of Clorox or other non-perfumed bleach to the chlorine side tank 1 to 4 mes a month. If there is
sulfur or high levels of manganese, we recommend once a week. If there is no sulfur odor, then add 1 cup of
Clorox to the chlorine side tank once a month.
Troubleshoo ng the Pro‐Ox 1650 Iron Filter
Measure the backwash flow rate by pu ng the system into a backwash mode and pu ng the drain tube
into a 5 gallon bucket and ming the flow rate. A 0.75 cubic foot system should flow at 5 gallons in one mi-
nute, so the 5 gallon bucket should fill in one minute. The 1.0 cubic foot system should flow at 7 GPM dur-
ing backwash.
In some cases, the Canature 165 valve has simply been programmed incorrectly. Double-check your se ngs
against those described above in step 18 of Assembly and Installa on Instruc ons ("PROGRAMMING", page
11) or consult your system's service manual for instruc ons. In some cases a nightly backwash is required
for best results. Adjust backwash frequency to every 1 to 2 nights if necessary.
What To Do If Your Filter Tank Does Not Sit Level On the Floor
Your black filter tank base is not glued to the bo om of your tank. Occasionally tank bases will become
crooked during shipment. If you find that that your tank does not sit level on the floor, you can easily adjust
it by holding the empty tank and rapping it on a concrete or solid floor once or twice in order to level it.