Fleck 5600 Softener Installation & Startup Guide
System Not Programmed Correctly – PROGRAM SETTINGS
In some cases, the Fleck 5600 may not be programmed correctly. Verify the correct programming by
following the steps 21‐33 earlier in the start‐up guide.
Brine Tank Not Filling With Enough Water
Sometimes if the brine tank is not filling adequately, it is possible that the float assembly in the tank is set too
low. You would want the float to be several inches above the air check valve inside the tank. This will allow
for enough water to be added to the tank before shutting the brine fill cycle. If necessary, pull the float
assembly rod up to the appropriate height, and cut the rod at that height, leaving while keeping the rubber
washers the adequate space to hold the float in place.
Filter Tank Does Not Sit Level on the Floor
Your black filter tank base is not glued to the bottom of your tank. Occasionally tank bases will become
crooked during shipment. If you find that that your tank does not sit level on the floor, you can easily adjust it
by holding the empty tank and rapping it on a concrete or solid floor once or twice in order to level it.
Page 16
www.cleanwaterstore.com
Rev 031714