Safety-Related Assembly And Installation Instructions; Intended Use; Changes And Alterations - Fasel Elektronik FCU6x00 Series Installation And Operating Manual

Sauna control units
Table of Contents

Advertisement

Safety
1.2

Safety-related assembly and installation instructions

1.3

Intended use

The FASEL sauna control units in the FCUxx00 series are designed exclusively for op-
eration and control of sauna cabins, saunas with humidity and infrared cabins. The con-
trol units are approved for operation in private homes and businesses.
Intended use
Claims of any kind due to damage as a result of non-intended use are excluded. The
operator bears sole responsibility for any damage caused by non-intended use.
1.4

Changes and alterations

Changes and alterations to the sauna control unit or to the installation can lead to un-
foreseen dangers.
Always obtain the written permission of the manufacturer before any technical changes
and alterations are made to the sauna control unit.
6
– DANGER!
– The control unit can be mounted directly on the outside of the cabin
or at another location, but not inside the cabin
– The control unit may be operated with a cover guard for the oven only
if one of the following options is available:
Timer function (can be locked in the service menu)
Remote start (remote operation) via option input or WEB-/APP-
Control
– According to VDE, for public saunas, an indicator lamp indicating that
the heater is switched on must be installed in the supervisor's room.
– This lamp can be connected to the clamp
– To disconnect from the mains, the power supply line must be
equipped with a fuse having a contact opening according to the re-
quirements of overvoltage category III for full separation.
– The main switch of the control unit must be freely accessible for de-
vices of the FCUxxxx series.
– The temperature sensor must be installed in such a way that it is not
affected by cold air flowing in from the outside.
WARNING!
Danger if used other than for intended purpose!
Any use apart from the intended use and/or any other use of the sauna
control system can result in dangerous situations.
For this reason:
– Use sauna control unit only as intended.
– The sauna control unit may be operated only within the permissible
ambient temperature limits and humidity limits.
– All specifications in the operating manual and installation instructions
must be strictly adhered to.
(FLE-STB).
Installation and Operating Manual / Version V 1.02

Advertisement

Table of Contents
loading

Table of Contents