Accessories/spare parts
C.2 Cables
The following table shows the technical properties of the bus cable ET-Connection standard.
Table C- 8
General information
Product type designation
Function
Degree of protection and protection class
IP65
IP67
Ambient conditions
Ambient temperature during mounting
minimum
maximum
Storage/transport temperature
Ambient temperature during transport and storage
minimum
maximum
Cables
Cable designation
Number of electrical wires
Design of shielding
Outside diameter of the inner conductor
Outside diameter of the wire insulation
Outside diameter of the cable sheath
Number of bending cycles
Permissible bending radius
One time bending, min.
Multiple bending, min.
Constant bending
Color of the cable sheath
Color of the wire insulation of the data wires
Weight per length
Mechanics/material
Type of cable outlet
Number of connectors
Connector housing material
Wire insulation material
Cable sheath material
Material property halogen free
Material property silicon free
* = Applies to cable lengths up to 10 meters.
100
Cables for ET-Connection
BUS CABLE ET-CONNECTION
To connect ET-CONNECTION devices with de-
gree of protection IP65/IP67
Yes
Yes
-30 °C
80 °C
-40 °C
80 °C
2Y(ST)CY 1x4x0.5/1.0-100-GN
4
Overlapped aluminum-lined sheet, coated with
shielding made of tin plated copper wires
0.5 mm
1.0 mm
5 mm
1000000; Trailing-chain suitable for 1 million
bending cycles with a bending radius of 100 mm,
a velocity of 4 m/s and an acceleration of 4 m/s²
20 mm
40 mm
100 mm
Green
White, yellow, blue, orange
34 kg/km
180° cable outlet
90° cable outlet (with angled connectors)
1 or 2
Metal
PE
PVC
No
Yes