Psu Configuration Policies - Huawei E9000 User Manual

Hide thumbs Also See for E9000:
Table of Contents

Advertisement

E9000 Server
User Guide
Table 2-5 Status description for the DC PSU operating status indicator
Color
Green
Red
Off

2.5.4 PSU Configuration Policies

The power consumption of the E9000 varies depending on the system configuration. PSUs are
configured based on power consumption.
Maximum Power Consumption of Major Components
Table 2-6 Maximum power consumption of major components
Category
Compute nodes
Issue 25 (2019-11-30)
Status and Meaning
l Steady: The PSU is running properly.
l Blinking (at 0.5 Hz): The PSU is in hibernation and supplies no power.
On: The PSU is not running properly.
NOTE
The causes are as follows:
l The PSU is in input overvoltage or undervoltage state.
l The PSU is in output overvoltage or undervoltage state.
l The PSU is supplying no power.
l A fan module alarm is generated, or a fan module fails.
Off: No power is supplied.
Component
CH121
CH140
CH140 V3
CH220
CH221
CH222
CH225 V3
CH240
CH242
CH242 V3
CH242 V3 DDR4
Copyright © Huawei Technologies Co., Ltd.
2 Overview
Maximum Power
Consumption
591 W
783 W
763 W
777 W
777 W
613 W
800 W
939 W
1089 W
l CH242 V3 8HDD: 1259
W
l CH242 V3 4HDD: 1265
W
1312 W
20

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents