Download Print this page

Led Indication - E+E Elektronik EE210 User Manual

Humidity and temperature transmitter for demanding climate control applications
Hide thumbs Also See for EE210:

Advertisement

CONNECTION DIAGRAM
EE210P (type C)
The EE210P remote probe for EE210-HT6xPC (4 ... 20mA, 2-wire) and HTx3xPC (RS485 interface) shall be ordered and it is supplied
as separate item. EE210P is to be connected to the EE210 by the user.
Install first the cable gland onto the EE210 enclosure.
Before connecting the probe, disconnect the EE210 power supply.
Insert the EE210P cable through the cable gland and connect it to the screw terminals according to the connection diagram below.
Please note:
EE210P is an intelligent probe with digital output and as such it is interchangeable. In case the probe or its cable gets destroyed or if a
longer cable is needed, please order a replacement probe according to EE210 data sheet. The replacement probe shall be installed as
described above.
Important:
Make sure that the cable glands are closed tightly for both EE210P probe cable and for the power supply and outputs cable. This is
necessary for assuring the protection class (IP class) of the enclosure according to EE210 specifi cation, as well as for stress relief at the
screw terminals on the EE210 board.

LED INDICATION

Green LED
- information to normal operation mode:
on
= everything OK
fl ashing = the main board does not recognize the
measurement electronics inside the sensing probe
off
= no power supply or main board failure
DISPLAY
Factory Setup:
The display shows the two parameters selected for output 1 and output 2 (accor-
ding to ordering code). For digital output versions the display shows RH and T.
User Setup:
The user can change the display layout to 1, 2 or 3 lines and select the
parameters to be displayed by using EE-PCS Product Configuration Software
(free download from www.epluse.com/configurator) and the optional EE-PCA
Product Configuration Adapter (not included in the scope of supply).
Important:
In the case of EE210-HT6 (4...20mA, two-wire version) the display operates only
if both outputs are connected.
Blue LED
- information during setup with the optional
E+E Confi guration Kit:
on
= E+E Product Confi guration Adapter (EE-PCA) is
powered, no communication in progess
fl ashing = EE-PCA powered, communication in progress
off
= EE-PCA not connected to the EE210

Advertisement

loading