LED INDICATION

Green LED
- information during normal operation:
on
= everything OK
fl ashing = the main board does not recognize the
measurement electronics inside the sensing probe
off
= no power supply or main board failure
DISPLAY
Factory Setup:
The display shows the two parameters selected for output 1 and output 2 (according to ordering
code). For digital output versions the display shows RH and T.
User Setup:
The user can change the display layout to 1, 2 or 3 lines and select the
parameters to be displayed by using EE-PCS Product Configuration Software (free download
from www.epluse.com/configurator) and the optional EE-PCA Product Configuration Adapter (not
included in the scope of supply).
Important: The EE210-HT6 (4...20 mA, two-wire version) with display operates correctly only if
both outputs are connected.
SELECTION OUTPUT SIGNAL U/I
The factory setup of the output signal and scaling corresponds to the type number as ordered.
The output signal (voltage or current 3-wire) can be selected with the DIP switch on the main electronics board (see picture PCB
EE210-HT2/3/5). This does not impact on the scaling of the outputs, which can be changed using EE-PCA and EE-PCS.
Examples
Factory setup: voltage output 0-5 V or 0-10 V corresponds to 0...100% RH.
After switching from U to I: current output 0...20 mA corresponds to 0...100% RH.
A change of the current output range for instance to 4-20 mA (3-wire) can be made subsequently with the EE-PCA and EE-PCS.
Factory setup: current output 0-20 mA corresponds to -10...50 °C.
After switching from I to U: voltage output 0-10 V corresponds to -10...50 °C.
A change of the voltage output range for instance to 0-5 V can be made subsequently with the EE-PCA and EE-PCS.

SCOPE OF SUPPLY

Model
EE210 according ordering guide
Cable gland
Mounting materials
Mounting fl ange
Inspection certificate according
to DIN EN10204 - 3.1
Quick Guide -
EE210 RS485 Setup
* EE210-P is not included in the Scope of Supply of the EE210 Type C
EE210
EE210
Wall mount
Duct mount
(Type A)
(Type B)
Blue LED
- information during setup with the optional
E+E Product Confi guration Adapter (EE-PCA):
on
= EE-PCA is powered, no communication in progess
fl ashing = EE-PCA powered, communication in progress
off
= EE-PCA not connected to the EE210
EE210
EE210-P
Remote version
Remote probe* for
(Type C)*
Type C
(2 pcs.)
Additionally for all
EE210 with RS485
interface

Advertisement