Blind controller insert without auxiliary input

Advertisement

Blind control system
Blind controller insert without auxiliary input
3 Function
Intended use
-
Controlling electrically driven blinds, rolling shutters and awnings
-
Operation with suitable shutter cover
-
Installation in appliance box according to DIN 49073
Product characteristics
-
Relay contacts of both running directions are mechanically interlocked
-
Supports sensor functions of the cover
4 Information for electrically skilled persons
4.1 Fitting and electrical connection
DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
Before carrying out work on the device or load, disengage all the
corresponding circuit breakers. Cover up live parts in the working environment.
Connecting and mounting the Venetian blind control
o
Connect venetian blind control according to connection diagram (Figure 2).
o
Install Venetian blind control in appliance box, terminals must be at the bottom.
Recommendation: Use deep accessory sockets.
o
Attach the frame and the cover.
o
Check function. If the blind/shutter moves in the wrong direction, exchange the
connections.
4.2 Installing sensor cable for covers with sensor evaluation
Installation instructions for sensors
i The sensor cable carries safety extra-low voltage (SELV). Observe fitting instructions
according to VDE 0100.
32537112
10860473
Figure 2: Connection of control
11.09.2013