Run Codes
Code
Display
0C
IDLE > DOWN LIMIT
0D
IDLE > UP LIMIT
0E
IDLE > MID STOP
0F
IDLE > NO LIMIT
10
OPENING > OPEN
BTN
11
OPENING > ONE BTN The 1- Button input was activated causing the door to move in the open
12
OPENING > RADIO
13
OPENING > AUX
OPEN
14
OPENING > OPEN
KEY
20
CLOSING > CLOSE PB The Close Pushbutton input was activated causing the door to move in the
21
CLOSING > ONE BTN
22
CLOSING > RADIO
24
CLOSING > CLOSE KP The Close Key (on the circuit board) was activated causing the door to move
2A
CLOSING > TCM CLS
2B
CLOSING > FDM CLS
30
HALT > WALL
BUTTON
31
HALT > ONE
BUTTON
32
HALT > RADIO
33
HALT > AUX. OPEN
34
HALT > KEYPAD KEY
35
HALT > N-O SAFETY
36
HALT > ODC STB
37
HALT > N-C SAFETY
38
HALT > MON. EDGE
39
HALT > DOOR FORCE The door stopped because the Speed of the Limit Assembly slowed down
3A
HALT > LOSS OF C/C
3B
HALT > SHUTDOWN
3C
HALT > DOWN LIMIT
3D
HALT > UP LIMIT
3E
HALT > MID STOP
Section 5: Troubleshooting
Detailed/Expanded Description
The door is at the Down Limit position.
The door is at the Up Limit position.
The door is at the Mid-Stop Limit position.
The door is at no established limit position.
The Open Pushbutton input was activated causing the door to move in the
opening direction.
direction.
The External Radio input was activated causing the door to move in the open
direction.
The Auxiliary Open input (on the TCM Module) was activated causing the
door to move in the open direction.
The Open Key (on the circuit board) was activated causing the door to move
in the open direction.
close direction.
The 1- Button input was activated causing the door to move in the close
direction.
The External Radio input was activated causing the door to move in the close
direction.
in the close direction.
The TCM Module sent a close signal causing the door to move in the close
direction.
The Fire Door Module sent a signal causing the door to move in the close
direction.
The door stopped because the Stop Pushbutton was activated.
The door stopped (and /or reversed) because the 1-Button input was
activated.
The door stopped and reversed because the Radio input was activated.
The door stopped (and /or reversed) because the Auxiliary Open input on
the TCM Module was activated.
The door stopped because the Stop Key was activated.
The door stopped and reversed because the Normally Open Reverse input
was activated.
The door stopped and reversed because the Safety Beam or Monitored Edge
with the Monitored Edge Interface Module was activated.
The door stopped and reversed because the Normally Close Reverse input on
the TCM Module was activated.
The door stopped and reversed because the Monitored Edge input on the
TCM Module was activated.
(Trolley Models only).
The door stopped (and /or reversed) because the constant contact activation
was removed before the door reached a limit.
The door stopped because the Hoist Interlock, External Interlock circuit
became active (opened) or the motor overheated.
The door stopped because it reached the Down limit position.
The door stopped because it reached the Up limit position.
The door stopped because it reached the Mid-Stop limit position.
Corrective Action
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
Check the door balance. Check the Clutch
adjustment to make sure it's not slipping.
Check for mechanical issues. Replace the
Limit Module. Replace the Main Control
Board.
None. User input was removed.
Check the Hoist Interlock switch and wires.
Check an External Interlock switch and
wires. If no External Interlock is use check
the gray jumper between the two EXT
INTLK terminals. Check for a hot motor.
None
None
None