Sensing Edges, Hardwired with Expansion Board
Actuating the operator by using constant contact on the CLOSE button will override non-functioning
external reversing devices, including sensing edges.
L'activation de l'operateur en util isant un contact constant sur le bouton FERMER annulera les dispositifs
d'inversions externes, y compris les systèmes de détection des bords.
MillerEdge® Wired "DC" ME or MT Series Monitored Sensing Edge
Installation with Timer Control Module (TCM) or Edge Sensing
Module (ESM).
ASO Sentir, GF Series Wired Monitored Sensing Edge Installation
with Edge Sensing Module (ESM).
1) Mount junction box to wall one half the door height plus 12 inches from floor. Fig. 11
2) Install Hard-wiring from operator and coil cord to junction box and secure with conduit clamps.
3) Connect hard-wiring from operator to coil cord with wire nuts and install junction box cover plate. These
are not polarity sensitive.
4) Connect coil cord to sensing edge with wire nuts.
5) Install hard-wires to TCM or ESM in operator. (See instructions included with expansion boards for detailed
installation and wiring)
Rolling Steel Door shown,
All installations are identical
Fig. 11
Sec-3.13
Section 3: Wiring
WARNING
!
AVERTISSEMENT
!
MON
EDGE
OR
MON
EDGE
Junction
Box
1/2 Door Height
+ 12in.
NOTE: DO NOT use take up
reels with Monitored Edge
systems
ESM Board
Terminals
EDGE STATUS
ASO
GREEN(ON)=WORKING
RED(ON)=OBSTRUCTION
&
RED(BLINKING)=FAULT
MillerEdge
GND
TCM Board
Terminals
GND
MillerEdge
Only without
Interface Module.