Sensing Edges, Hardwired
Actuating the operator by using constant contact on the CLOSE button will override non-functioning
external reversing devices, including sensing edges.
L'activation de l'operateur en util isant un contact constant sur le bouton FERMER annulera les dispositifs
d'inversions externes, y compris les systèmes de détection des bords.
MillerEdge® Wired "DC" ME or MT Series Monitored Sensing Edge
Installation with Interface Module.
Right hand installation shown, Left hand installation mirrored. Fig. 9
1) Mount junction box to wall One half the door height plus 12 inches from floor.
2) Install Hard-wiring from operator and coil cord to junction box and secure with conduit clamps.
3) Connect hard-wiring from operator to coil cord with wire nuts and install junction box cover plate. These
are not polarity sensitive.
4) Install hard-wires to ODC STB terminals in operator.
5) Attach coil cord to Monitored Edge Interface Module junction box and secure with conduit clamps.
6) Install wires to Monitored Interface Module as shown.
7) Install cover plate.
NOTE: DO NOT use take up reels with Monitored Edge systems
NOTE: Installer must enable ODC STB in Calibration mode (see programming section)
Rolling Steel Door shown,
All installations are identical
Sec-3.11
Section 3: Wiring
WARNING
!
AVERTISSEMENT
!
Fig. 9
Control Wire
Terminals
ODC
ODC
STB
STB
Junction
Box
Interface Module
Black
1/2 Door Height
+ 12in.
Monitored
Safety Edge
MillerEdge®
Install
Red
COIL
CORD
Red
White