Interlock Switches, Sectional Doors
Optional external interlock switches are required with some Sectional or Rolling Steel Doors to prevent the
door from operating under certain conditions including the following: Fig. 5
• If the door is equipped with a functioning door lock, an interlock switch (A) must be installed to prevent
electric operation when the lock is engaged.
• If the door is equipped with a pedestrian pass-through door, an interlock switch (B) must be installed at
the pass-through door in order to prevent electrical operation when the pass-through door is open.
• The Switches must be set in the field.
NOTE: If External Interlock is used, THE JUMPER WIRE BETWEEN THE
EXT INTLK TERMINALS MUST BE REMOVED.
Pass door interlock:
Section 3: Wiring
B
Should be open when
door is open.
Closed when door
is closed.
Side lock interlock:
Should be open when door
is locked. Closed when door
is unlocked.
SWITCH
075412-0000
(N.O.)
A
Fig. 5
CONTROL SIGNAL TERMINAL STRIP
EXT
INTLK
ANGLE
405964-0000
TRACK
STANDARD
SLIDELOCK
SWITCH (N.C.) P/N 110324.0001
For Sectional Door
EXT
INTLK
* REMOVE
*
JUMPER
WHEN
INSTALLING
EXTERNAL
INTERLOCK
Sec-3.8