Zetor 8621 Forterra turbo Operator's Manual page 19

Table of Contents

Advertisement

CAB FILTRATION
Check and eventually clean cab filters
located under the roof in front part. Filter
exchange interval depends upon dust-
iness of working condition. The partial
regeneration of filters can be done by
shaking-out or blowing by press air.
Filters are accessible after removing of
grills located in front of cab roof.
PREVENTIVE DAILY SERVICE
F 17
HITCHES
Check the status of hitches and attach-
ments including the trailer.
19
F 18
AFTER OPERATION WITH FRONT
IMPLEMENTS
Remove the front mask to be able to
blow out impurities outside the tractor.
Clean the front part of radiators (radia-
tors of transmission, AC condenser) by
the press air, blow it in direction from the
engine. Remove the rest of impurities
under the bonnet, otherwise their re-
peated suction into the cooling system
might appear.Inspect front three-point
hitch hydraulic circuit for leaks.
F 19

Advertisement

Table of Contents
loading

Table of Contents